background image

E-2

Select the LectroBolt (screw with red sleeve) length that corresponds
to the correct door thickness as noted in this chart:

LectroBolt
here

Mounting screws

LectroBolt
screw

H

T

L

J

J

K

G

F

This addendum replaces the existing Section E in your E-Plex 5000
Cylindrical Installation Instructions.

E. INSTALLING & HANDING THE INSIDE UNIT ASSEMBLY

Note

: Installing levers to the unit assemblies before mounting them may

ease initial installation.

Door Thickness

LectroBolt Size

Mounting Screws Size

1

3

8

" to 1

1

2

"

2

3

8

"

2

1

2

"

(35 mm to 38 mm)

(60 mm)

(64 mm)

1

5

8

" to 2"

2

3

4

"

2

7

8

"

(41 mm to 51 mm)

(70 mm)

(73 mm)

2

1

8

" to 2

1

4

"

3"

3

1

4

"

(54 mm to 57 mm)

(76 mm)

(83 mm)

R

E-1

Inside Face of Plate

Remove screws and rotate this plate
inside face out to change from left hand
to right hand. There should be an “R” for
“Right Hand” stamped on the inside face.
Reinstall screws.

Inside Housing set

up for LEFT HAND

Inside Housing set up

for RIGHT HAND

R

E-3

Insert spindle (F) into 

the hole (G) as shown 
below until it “snaps” 
into place. Place the 
outside trim (K) onto 
the door, inserting the 
spindle (F) into the 
hole in the door (H). 
Put the thumbturn (T) 
in a vertical position 
and place the trim 
assembly on the door 
so that the spindle (F) 
engages the thumbturn. 
Ensure the red collar (J) is seated into its mounting hole. Carefully 
push the inside housing (L) flush against the door.

Warning

: If using a power drill, please be careful not to over-tighten as

this could cause damage to the mounting screws and threads.

E-4

Insert LectroBolt through the red inside
housing hole marked with the lightening
bolt symbol.

For now, only partially tighten the
LectroBolt to keep the red 
collars in position.

Then, insert and tighten the other three
mounting bolts.

Finish tightening the LectroBolt to
secure the lock on the door.