Mounting Instructions 

82132/33 Code-Combi B with Plastic Control Unit 

 

4  Cabling 

 

 

Connectors to be plugged in as follows: 

 

Marking on the lock case 

Cable connection for 

Marked 

„input unit“ 

6-pole connecting cable to the electronic input system 

Marked 

„power“ 

4-pole operating voltage (battery compartment) 

 

 

Confusion of the connecting cables does not produce any damage of the electronic system of the lock. The lock will not be 
operable in this case and must be connected correctly in accordance with the circuit diagram. 

 

 

Always press the latching clip of the plug against the plug housing for disconnecting the plugs and sockets. Do not pull out 
plug reaching for the plug housing or the cable. 

 

 

Make sure that the connecting cable is not damaged during installation. Cable sheathing or flexible leads must not be 
impaired, otherwise hazard of a short circuit. Protect the cable by protective hoses or plastic pipes in the area of transition 
and moving parts. Make sure also that the cable is not buckled or installed in pinched condition.  

 
 

5  Adjustment /final check 

 

 

The bolt is correctly adjusted when the bar dolly after slight clockwise turning jumps back by resilience to its horizontal 
home position. After turning of the bar up to stop position, the bar dolly may remain in stop position. 

 

 

Make sure when opening the lock that the bar dolly can be moved smoothly. 

 

 

Function of the lock to be tested in accordance with the operating instructions. Also check the mechanical opening by the 
two way key.  

Содержание 82132

Страница 1: ...loc batteries only Low quality batteries may cause oxidation which results in a functional failure of the lock Avoid residual crystalline moisture in the cabinet e g from varnishing so as to prevent attack of the electrical contacts Make sure that ingress of dirt or detergents e g remaining fillers or cold cleaners is prevented Do not grease oil the lock or key 2 Mounting instructions for lock and...

Страница 2: ...an 100 sq mm see mounting drawings on Page 5 and following The lock is designed for installation in secure storage units made of steel Installation in storage units consisting of other material e g plastic is not allowed Do not apply any kind of force e g hammer blows for screw fitting and adjustment of the lock Lock to be installed covered and so as to prevent opening by boring The two way key mu...

Страница 3: ...ning of the boltwork via two M4 threads on the front end of the bolt head Optional fastening of the boltwork via a drift pin in the bolt head The bolt was according to EN1300 with a permanent load of 2 5 N over 10 000 cycles tested These load should not be exceeded permanently 3 Mounting of the control unit Two possibilities are available for fastening of the control unit 1 from the inner side of ...

Страница 4: ...not pull out plug reaching for the plug housing or the cable Make sure that the connecting cable is not damaged during installation Cable sheathing or flexible leads must not be impaired otherwise hazard of a short circuit Protect the cable by protective hoses or plastic pipes in the area of transition and moving parts Make sure also that the cable is not buckled or installed in pinched condition ...

Страница 5: ... 1 82132 33 Code Combi B with plastic control unit 98851 0001 Lock mounting position Control unit mounting position 3 2 6 1 1 1 3 9 6 1 Depth of battery compartment approx 60 mm 43 24 5 34 5 O 3 2 3 2 O Separate battery compartment Keyhole in lock Cable gland 10 mm or Ø 11 25 0 05 mm 97 59 23 5 59 83 5 33 Door penetrations ...

Страница 6: ...3 Code Combi B with plastic control unit 98851 0002 Lock mounting position Control unit mounting position Depth of battery compartment approx 60 mm 43 24 5 34 5 O 3 2 3 2 O 6 1 3 2 1 1 3 9 6 1 97 59 23 5 59 33 83 5 Cable gland 10 mm or Ø 11 25 0 05 mm Separate battery compartment Keyhole in lock Door penetrations ...

Страница 7: ...Code Combi B with plastic control unit 98852 0001 Lock mounting position Control unit mounting position Depth of battery compartment appprox 60 mm 43 24 5 34 5 O 3 2 3 2 O 9 1 1 3 6 1 3 2 6 1 59 59 97 97 23 5 23 5 85 Cable gland 10 mm or Ø 11 25 0 05 mm Separate battery compartment Keyhole in lock Door penetrations ...

Страница 8: ...ode Combi B with plastic control unit 98852 0002 Lock mounting position Depth of battery compartment approx 60 mm 43 24 5 34 5 O 3 2 3 2 O 6 1 3 2 9 1 1 3 6 1 23 5 23 5 97 97 59 59 90 Cable gland 10 mm or Ø 11 25 mm 0 05 mm Separate battery compartment Keyhole in lock Control unit mounting position Door penetrations ...

Страница 9: ...ode Combi B with plastic control unit 98852 0003 Lock mounting position 3 2 6 1 1 1 3 9 6 1 Depth of battery compartment approx 60 mm 43 24 5 34 5 O 3 2 3 2 O 23 5 23 5 97 97 59 59 90 Cable gland 10 mm or Ø 11 25 mm 0 05 mm Separate battery compartment Keyhole in lock Control unit mounting position Door penetrations ...

Страница 10: ...Code Combi B with plastic control unit 98852 0004 Lock mounting position Depth of battery compartment approx 60 mm 43 24 5 34 5 O 3 2 3 2 O 6 1 3 2 1 1 3 9 6 1 23 5 23 5 97 97 59 59 90 Separate battery compartment Keyhole in lock Control unit mounting position Cable gland 10 mm or Ø 11 25 mm 0 05 mm Door penetrations ...

Отзывы: