Disassemble and remove the lock
body from the container or door.
Turn the lock over so the cables
and plastic tube retainer are
visable.
Insert the T-6 Torx Bit, supplied
with the X-09/X-10 Service Tool,
into the tool and remove the
screw holding the tube retainer
on to the lock case.
Carefully remove the tube
retainer.
Note: The Ground Contact will
probably be stuck to the Tube Retainer
with grease, please be aware of this and
make sure it is in place when re-
installing the tube retainer. The cable
plug should now be visable.
Note:
The X-10 plastic tube retainer is
shorter and is located in a different spot.
If using an X-10 ribbon cable assembly
kit, make sure to use the plastic tube
retainer that’s on the X-09.
Remove the cable plug and
damaged cables and discard.
Remove the protective cover off
of the contacts of the new cables
and insert them into the lock case
as shown.
Replacing the Ribbon Cable on the X-09/X-10
TM
X-09
X-10
X-10
X-09
(1)
(2)
(3)
(4)