TIME DELAY
• Delay Period 1 - 99 minutes
• Open Period 1 - 19 minutes
COMBINATION LENGTH
A combination length from six (6) to nine (9) digits may be selected.
NOTE: To maintain the VdS Class 2 and EN 1300 Class B certification when the duress alarm feature
is used, a combination length of 7 digits or longer must be selected.
LOCK USERS
Manager
• Open Lock
• Change Combination
• Enable/Disable Users
• Delete Users
• Set Time Delay Values
• Audit Lock
Up to 9 Users
• Open Lock
• Change Combination
STANDARD LOCK FEATURES
Wrong Try Penalty
• Entry of four (4) consecutive invalid combinations initiates a five (5) minute delay penalty.
Lock responses during the penalty period are as follows:
- The LED will flash every ten (10) seconds.
- If any key is pressed, the Lock will flash the LED and beep three times.
• Once the penalty period has ended, two (2) consecutive invalid combinations will initiate another
five (5) minute penalty period.
Low Battery Warning
• Repeated audio/visual signals (LED flashes/beeps) during Lock opening indicate the battery is low
and should be replaced immediately.
• If the battery level becomes too low to safely operate the Lock, pressing any key will initiate the
low battery warning. The battery must be replaced before the Lock will operate.
Audit Records
• Lock records the last 63 events in non-volatile memory.
• Audit file cannot be deleted from the Lock.
• Only the Manager can audit the Lock.
• ComboGard Pro auditing software and an Interface Adapter are required to retrieve a Lock audit.
LOCK OPERATING CONVENTIONS
• If a mistake is made while entering keystrokes, wait thirty (30) seconds and repeat operation.
• To access lock commands, enter combination and hold down the last digit until Lock double
signals and the LED stays on.
• In Dual Mode, two combinations are required to operate the Lock.
NOTE: In Dual Mode, a valid User combination must be entered first, followed by the Manager
combination to access the following Manager Commands: 1, 2, 3, 7 and 9.
• Lock must be opened within 4 seconds once a valid combination has been entered.
• To open a container with a Swing Bolt Lock, turn the container handle to the open position and
open the door.
• To open a container with a Dead or Spring Bolt Lock, turn the keypad or dial to retract the bolt
and open the door.
• When closing a container, verify that it has been secured.