3
2
Part Number
Description
4000006-H
Everest Ground Lug, 13mm Hex
Components
Assembly
1
!
To attach the Everest Ground Lug, insert the MK3 slot nut of the preassembled ground lug into the top channel
of the CrossRail. While slightly lifting the plastic tabs, rotate 90 degrees clockwise to engage the MK3 into the
channel. Ensure the bonding teeth are perpendicular to the rail channel.
2
!
Torque the M8 bolt to 10 ft-lbs using a
13 mm deep socket wrench.
Tools overview
13 mm dep socket
T
Torque 10 ft-lbs
10-50 ft-lb
(6 - 35 Nm)
7/16" socket
T
Torque 35-60 in-lbs
Important note
!
CrossRail components are required to be electrically bonded and
grounded via the Everest Ground Lug or Burndy’s WEEB Lug 10 and the
use of #6 or #8 AWG solid copper wire. A minimum of one lug is required
per each independent row of modules. The Everest Ground Lug must be
attached to the top channel of CrossRail, as shown.