10 For Professional Technical Support call 1-844-242-2475
2. Install screen surround the foot valve, protect the foot valve
assembly from fish, trash, etc. Position the foot valve 5 feet
above bottom of well and
It should also be at least 10 feet
below the water level in order to prevent the pump from
sucking air.
(Fig 2)
3. Cement
1-1/4in. PVC MPT×S Male Adapter
into
1-1/4 in.
PVC rigid Pipe.
Install
1-1/4in.PVC TEE FPT×FPT×FPT
to
adapter. One end of horizontal port install another
1-1/4in.
PVC MPT×S Male Adapter
and
1-1/4 in. PVC rigid Pipe
.
Add sections of pipes to reach the 1-1/4in. PVC Slip ×Slip
Union (optional). (Fig. 3)
2. Well To Pump Connection
1. Thread
1-1/4in. PVC MPT×S Male Adapter
into pump.
Cement a short horizontal
1-1/4 in. PVC rigid Pipe
into
adapter. (Fig.1) (For model WPS05003K/WPS07503K)
Or thread
1in. ×1-1/4in. PVC MPT×S Reducer Male
Adapter
into pump. Cement a short horizontal
1-1/4 in. PVC
rigid Pipe
into adapter. (For Model WPS05002TK)
2.
For pre-charged
tank connection
.
Cement a
1-1/4in.
PVC Slip× Slip Union
into a short horizontal 1-1/4 in. PVC
rigid Pipe. Slopes all inlet piping slightly upward from well to
the pump to prevent trapping air.(Fig.2)
For standard tank connection
. Cement
1-1/4in. ×1-1/4in.
×3/4in. PVC S×S×FPT Reducer Tee Fitting
into a short
horizontal 1-1/4 in. PVC rigid Pipe and cement another a
short horizontal 1-1/4 into the side of the tee fitting, then
install
3/4in. MIP×1/2in.FIP Lead-Free Brass Hex Bushing
Fitting
to the port of 3/4in, thread and another
1/2in.
MIP×1/8in.FIP Lead-Free Brass Hex Bushing Fitting
to
the bushing fitting.