63414A/KTI

-

63427A 

TROUBLESHOOTING

PROBLEM: JACK WILL NOT LIFT RATED LOAD
POSSIBLE CAUSE:

 

The release valve is not closed. 

ACTION:

 

Turn the valve clockwise tightly. 

POSSIBLE CAUSE:

 

Fluid level low.

ACTION:

 

POSSIBLE CAUSE:

 

Pump seals and back-up ring defective.

ACTION:

 

 Clean oil passages, replace seals and renew oil. (Must be serviced by qualified service center). 

PROBLEM: JACK WILL NOT LIFT TO ITS FULL HEIGHT
POSSIBLE CAUSE:

 

Fluid level low.

ACTION:

 

POSSIBLE CAUSE:

 

The hydraulic system is filled with air.

ACTION:

 

Follow the instructions under Setup and Operating Instructions to purge air from hydraulic system.

PROBLEM: JACK WILL NOT LIFT SMOOTHLY OR JACK FEELS SPONGY
POSSIBLE CAUSE:

 

The hydraulic system is filled with air.

ACTION:

 

Follow the instructions under Setup and Operating Instructions to purge air from hydraulic system.

WARRANTY 

K-Tool International warrants that all jacks and service-related equipment will be free from defects in material and workmanship for a 
period of 2 years following the original date of purchase. This warranty is extended to the original retail purchaser only. If any jack or 
service-related item proves to be defective during this period, it will be replaced or repaired, at K-Tool International’s option, without 
charge. This warranty does not apply to damage from accident, overload, misuse or abuse, nor does it apply to any equipment which 
has been altered or used with special attachments other than those recommended. 

K-Tool 

I

nternational HD and XD service-related equipment 2 Year Limited Warranty.

Michigan 

Содержание XD KTI-63414A

Страница 1: ...MANUAL KTI 63414A KTI 63427A SPECIFICATIONS KTI 63414A KTI 63427A Capacity 4 Ton 8 Ton Low Height 24 4 5 24 Maximum Height 44 3 10 43 7 10 KTI 63414A www P65Warnings ca gov Cancer and Reproductive Harm WARNING KTI 63427A Complies with ASME PASE 2014 Safety Standard ...

Страница 2: ...loads overloading off centered loads use on other than hard level surfaces and using equipment for a purpose for which it was not designed These long stroke jacks were not designed to lift vehicles They were designed to be used as original equipment by manufacturers of shop cranes K Tool International cannot be held responsible for these jacks used in shop cranes and other equipment designed and o...

Страница 3: ...system 4 Follow the operating instructions that accompany the K Tool International shop crane PREVENTATIVE MAINTENANCE This is the safety alert symbol used for the PREVENTATIVE MAINTENANCE section of this manual to alert you to potential personal injury hazards Obey all instructions to avoid possible injury or death IMPORTANT Any jack found to be defective as a result of worn parts due to lack of ...

Страница 4: ...E CAUSE The hydraulic system is filled with air ACTION Follow the instructions under Setup and Operating Instructions to purge air from hydraulic system WARRANTY K Tool International warrants that all jacks and service related equipment will be free from defects in material and workmanship for a period of 2 years following the original date of purchase This warranty is extended to the original ret...

Страница 5: ... Clip 3 21 Handle Yoke Linkage 1 N O I T P I R C S E D O N T R A P O N M E T I QTY 24 Pump Core 1 25 Pump Ring 1 26 O Ring 1 27 J Type Dustproof Ring 1 28 Pump Body 1 29 Sealing Ring 1 30 Screw 1 31 Square Sealing Ring 1 32 Pressure Set Screw 1 33 Pressure Set Spring 1 34 Pressure Set Valve 1 35 Square Sealing Ring 1 36 KTP63414A36 Release Valve incl 36 38 1 37 Lever 1 38 Screw 1 Only available in...

Страница 6: ... Clip 3 21 Handle Yoke Linkage 1 N O I T P I R C S E D O N T R A P O N M E T I QTY 24 Pump Core 1 25 Pump Ring 1 26 O Ring 1 27 J Type Dustproof Ring 1 28 Pump Body 1 29 Sealing Ring 1 30 Screw 1 31 Square Sealing Ring 1 32 Pressure Set Screw 1 33 Pressure Set Spring 1 34 Pressure Set Valve 1 35 Square Sealing Ring 1 36 KTP63427A36 Release Valve incl 36 38 1 37 Lever 1 38 Screw 1 Only available in...

Отзывы: