4.  Connecting of the Cable

Outdoor Unit

Indoor Unit

1). Remove the access door from the unit by loosening 

Connect the power connecting cord to the indoor unit
by connecting the wires to the terminals on the control
board individually in accordance with  the outdoor  unit 
connection.

the screw. Connect the wires to the terminals on the 
control board individually as the following.

2). Secure the power connecting cord onto the control 
board with cable clamp.

3). Reinstall the access door to the original position 
with the screw.

4) Use a recognized circuit breaker for 24K.30K model 
between the power source and the unit. A disconnecting 
device to adequately disconnect all supply lines must be fitted.

Note: Above cables shall be approved by HAR  or SAA.

Note: For some models, it is necessary to remove the cabinet to 
connect  to indoor unit terminal.

Installation Instructions

 Caution:

1. Never fail to have an individual power circuit specifically for the air conditioner. As for the 
method of wiring, refer to the circuit diagram posted on the inside of the access door .

2.Comfirm that the cable thickness is as specified in the power source specification. 
(See the cable specification table below)
 
3.Check the wires and make sure that they are all tightly fastened after cable connection.

4. Be sure to install an earth leakage circuit breaker in wet or moist area.

Capacity (Btu/h)

7K,9K

H05RN-F

H05VV-F

H05VV-F

H05VV-F

H05RN-F

H05RN-F

H05RN-F

H05RN-F

H05RN-F

H05RN-F

H07RN-F

12K

15K,

18K

16K,

22K,24K

Power connecting cord

Power   cord

 Type

 Type

 Type

 Normal cross
- sectional area

 Normal cross
- sectional area

 Normal cross
- sectional area

Power connecting cord1(for heat pump)

Cable Specifications

2

0.75mmX 2

2

0.75mmX 2

2

0.75mmX 2

2

1.0mmX 3

2

1.0mmX 3

2

1.5mmX 3

2

2.5mmX 3

2

1.0mmX 3

2

1.5mmX 3

2

0.75mm X6(heat pump)

2

0.75mm X4(cool only)

1

1

Chassis

Cabinet

Front panel  

Terminal (inside)

Access door
Terminal(inside)

Indoor unit

Outdoor unit

The figures in this manual are based on the external view of a standard model.
Consequently, the shape may differ from that of the air conditioner you have selected.

2

(1.5mmX 3)

2

1.0mmX 3

2

(1.5mmX 3)

30K

H07RN-F

2

4.0mmX 3

H05RN-F

2

0.75mm X4

H05RN-F

2

0.75mmX 2

H07RN-F

Содержание TAC-09CHSA

Страница 1: ...fully before using the product USER S MANUAL Split Wall Mounted Air Conditioner MODEL TAC 09CHSA TAC 12CHSA TAC 18CHSA TAC 24CHSA K STAR INTERNATIONAL GROUP INC TollFree 800 893 2169 E Mail info kstarus com www kstarus com GG25Eng C US ...

Страница 2: ... batteries or is energized User can preset the remote controller type depending on the air conditioner type you have purchased as follows Press any button when the flashes If you dont press any button within 10 seconds the remote controller is pre set as Heat Pump automatically the symbol will flash from Cool and HEAT alternatively heating symbol then Heat Pump is set Press any button when the coo...

Страница 3: ...s injury etc 1 1 SLEEP FAN TIMER SWING ON OFF MODE MED LO SWING AUTO HI DRY FAN HEAT COOL FEEL SLEEP TIMER ON OFF Use correct power supply in accordance with the rating plate requirement Otherwise serious faults or hazard may occur or a fire maybe break out If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a haz...

Страница 4: ...take Air Intake Air Outlet Louver Vertical Adjustment Louver Horizontal Adjustment Electrostatic Filter optional Charcoal Filter optional Air Filter Remote Controller Front Panel Emergency Panel Display Panel Note Condensate water drains at COOLING or DRY operation Identification of Parts Indoor Unit Outdoor Unit 1 1 Drain Hose Connection Cord Pipes and Power Air Outlet ...

Страница 5: ...dicator It lights up when power supply is on Temperature display Switch display of environmental tempe rature and setting temperature Temperature display Switch display of environmental tempe rature and setting temperature Signal Receives Receive signal from the remote controller TIMER RUN SLEEP POWER Used to control the unit when the remote controller is out of work This operation way is suitable...

Страница 6: ...e Comfortable SLEEP Used to start and stop operation Used to adjust airflow direction Used to select TIMER operation Signal Transmitting Window Transmits signals to the system Setting Display Transmitting display Time setting display Temperature setting display setting temperature adjustment display During feel mode 1 2 3 4 8 5 6 7 9 10 11 12 13 14 9 SUPER button optional 10 ECO button optional 11...

Страница 7: ... time or each time the batteries are replaced as they are discharged the remote controller mades a short Auto Test all the symbols can be displayed are shown on the screen and keep 2 seconds then the symbol will flash from For cooling only air con please press any button when the cooling symbol is flashing the the remote controller has been set as cooling only For cooling and heating air con pleas...

Страница 8: ...onditioner aim the remote controller to the signal receptor The remote controller will operate the air conditioner at a distance of up to 7m when pointing at signal receptor of indoor unit Remote controller holder Signal receptor Remote Controller Remote Controller Please slide and remove the cover Exchange the batteries Install the cover 1 2 3 Attention to the and marks Slide the cover upwardly i...

Страница 9: ...e FEEL position 1 2 Operates by selecting automatically the operation mode HEAT DRY FAN COOL depending on the room temperature during staring Press the button or the button When the button is pushed the temperature will increase 1 When the button is pushed the temperature will reduce 1 After temperature will increase 2 the indicator will not change After temperature reduce 2 the indicator will not...

Страница 10: ...econds SLEEP operation is switched from Normal SLEEP to SLEEP alternatively Comfortable Used to set or cancel sleep operation This function is invalid in fan and dehumidify mode This function is invalid in SUPER mode too Switches OFF the appliance automatically after 10 hours in Normal SLEEP mode Normal SLEEP only 2 after the Unit t s start Select the operating mode and then press SLEEP button the...

Страница 11: ...sty environment Stop the appliance and remove the air filter 1 Open the front panel 2 Press the handle of the filter gently from the front 3 Grasp the handle and slide out the filter soft cloth to clean it Use a dry and Grasp position a and pull outward to remove the front panel a a b b Maintenance 1 1 At the end of the season Set temperature to 30 for about half a day and perform the Cooling oper...

Страница 12: ... minutes later In HEATING operation the appliance will defrost de ice automatically to raise efficiency This procedure usually lasts 2 10 minutes During defrosting fans stop operation After defrosting completes it returns to HEATING mode automatically Protection Features of protector Inspection After using for long time the air conditioner should be inspected on the following items Overheat of the...

Страница 13: ... power supply and connect back 2 3 seconds later Changing mode during operation 3 minutes will delay This odor may come from another source such as furniture cigarette etc which is sucked in the unit and blows out with the air Caused by the flow of refrigerant in the air conditioner not a problem Defrosting sound in heating mode The sound may be generated by the expansion or contraction of the fro...

Страница 14: ...hould be over 150mm should be over 2000mm should be over 300mm Installation must be performed in accordance with the national wiring standards by authorized personnel only Above figure is only a simple presentation of the unit it may not match the external appearance of the unit you purchased Installation Instructions Installation Diagram 1 1 NOTE NOTE Very Important Installation must done by a re...

Страница 15: ... is no obstacle near the air outlet and air can be easily blown to every corner Where piping and wall hole can be easily arranged Keep the required space from the unit to the ceiling and wall according to the wiring diagram Where the air filter can be easily removed Keep the unit and remote controller 1m or more apart from television radio etc Keep as far as possible away from fluorescent lamps Do...

Страница 16: ...eve through the wall hole to keep the wall tidy and clean Drill a hole on the wall The hole should tilt a little downward toward outside Decide the position of hole for piping according to the location of mounting plate 2 Drill a Hole for Piping Keep the mounting plate horizontally with a horizontal ruler or dropping line Drill holes of 32mm in depth on the wall for fixing the plate Insert the pla...

Страница 17: ...er cord 1 for heat pump Power cord Defrost cable for heat pump Drain hose prepared by user A Insert the pipe fixer to the slot B Press to hook the pipe fixer onto the base Base Base Base Piping fixer Piping fixer Hook here Insert here drain hose drain hose large pipe large pipe small pipe small pipe b Pre tighten them with fingers at first then use the wrenches For T3 climate kind models 18K and 2...

Страница 18: ... to the circuit diagram posted on the inside of the access door 2 Comfirm that the cable thickness is as specified in the power source specification See the cable specification table below 3 Check the wires and make sure that they are all tightly fastened after cable connection 4 Be sure to install an earth leakage circuit breaker in wet or moist area Capacity Btu h 7K 9K H05RN F H05VV F H05VV F H...

Страница 19: ...t the condensate water Just install the drain port and rubber washer to the chassis of the outdoor unit then connect a drain hose to the port as the right figure shown The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the compressor After connecting the indoor and outdoor units evacuate air and moisture from refrigerant cycle using a vacuum pump as sho...

Страница 20: ... 2 L N L 1 N 1 2 3N Cooling Heating 12 3N Cooling Only 1N Connetting outdoor unit Connetting indoor unit 1 L N 1 L N Indoor Unit Outdoor Unit 09K 12K 15K 18K indoor interconnection cable sketch map 22K 24K indoor and outdoor interconnection cable sketch map 09K 12K 15K 18K outdoor interconnection cable sketch map Split frequency conversion air conditioner interconnection cable means Heating and co...

Страница 21: ...on of at least 3 mm placed in an accessible position even after installation 1 1 NOTE NOTE Test Running Connect to the power source check if the function selection keys on the remote controller are working properly Check if the room temperature adjustments and timer settings are working properly Check if the drain is smooth Check if there is any abnormal noise or vibration during operation Check i...

Отзывы: