![K-Star 3388C IS Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/k-star/3388c-is/3388c-is_operating-instructions-manual_648596006.webp)
INSTALL MOUNTING
PLATE AND ANGLE IRON
1.
Fix the instruction paper onto the
ceiling. Drill holes as the paper show.
2.
Put the drywall anchors into the holes
and pick out the mounting plate and
use 12 pcs mounting screws to fix the
plate onto the ceiling.(If for concrete
ceiling, pls use the 8 pcs of explode
screws).
3.
Put out the 8 pcs of angle iron, use 8
pcs of mounting screws(4*14mm) with
washers and nuts to fixe 4 pcs angle
iron onto the mounting plate.
4.
Adjust the height X of the chimney( as
shown on the picture 1), use 16 pcs of
munting
screws(4*14mm)
with
washers and nuts to fixe the other 4
pcs angle iron onto the angle irons
which have been installed.
INSTALL THE DUCTWORK
NOTE: To reduce the risk of fire, use only metal ductwork.
1. Deside where the ductwork will run between the hood and the
outside.
2. A straight, short duct run will allow the hood to perform most
efficiently.
3. Let the one side of the duct go outside through the hole of 6.7’’ as
shown.