DC LATCHING SOLENOID START-UP PROCEDURE:

Because some DC Latching solenoids will default to the latched (open) position before 
installation, the valve will appear to be stuck open. It is necessary to energize all zones
to unlatch the coil and close the valve prior to installation. From the Manual Operation 
Screen, select each active station and run for 2 seconds each. This will unlatch the
coil and close the valve on each station should the plunger be latched magnetically
prior to installation.

Resetting the security key:

 If you need to reset the security key (the passcode set 

on the device), disconnect the battery (or batteries). Use one of the batteries to make 
a reverse connection on the battery terminal (positive to negative). Hold this connection 
for 5 seconds. 

Launch the App and Add the device to your account by following steps 1-5.  
Go to the Edit screen and type in a new security key.

ACCESSING THE APP FROM A DESKTOP OR LAPTOP:

While the BLUE app is designed for use in the field on a smartphone or tablet, 
it is accessible on a desktop or laptop computer at: 

www.krainconnect.com

.

Reconnect and 
insert the battery.

Make contact on the battery terminals 
for 5 seconds with battery reversed. 

Rain Sensor 

(yellow)

Stations (red)

PARTS DIAGRAM

BLUE

Common (black)

Mounting Holes

Battery 

Enclosure

Содержание BLUE

Страница 1: ...INSTRUCTIONS FOR USE GET THE APP Using the camera on your smartphone scan a QR code to get the free BLUE app BLUE App Store Google Play ...

Страница 2: ...tion On Android location services must be enabled in order for the App to connect to the BLUE device 3 Launch the App and Create an account Launch the app from your device and the first thing it will ask you is to create or register an account or Sign in Click here 4 Creating your account Enter your email address and create a password then push SIGN UP This will bring you to the REGISTER page Fill...

Страница 3: ...CCESSORIES 1 Mount the unit in on the valve box 2 Use only 9V solenoid pulse coils K Rain part number P3008114 NOTE Some DC latching 9V coils come from the manufacturer already latched Please follow the start up procedure for DC latching solenoids on page 17 Wiring Solenoid 9V Solenoid Pulse 24 Vac 13mm 1 2 13mm 1 2 13mm 1 2 13mm 1 2 SS 1 2 3 4 C SS 1 2 3 4 C 03 04 3 Wiring a rain sensor Cut the y...

Страница 4: ...MANUAL OPERATION Allows you to manually run a station for up to 12 hours or manually run a complete program The status of the rain sensor does not affect manual control TO RUN A PROGRAM Choose the Program then push RUN TO RUN A STATION Choose the Station set the amount of time you wish it to run then push RUN The display will show you when the expected completion of your manual operation will be T...

Страница 5: ...dget of run time setting up to 8 start times and station duration You can also rename programs with more intuitive descriptions Weekday Schedule Weekend Schedule You can add up to 8 independent programs using the sign in the upper right corner of this screen 07 08 CHANGE PROGRAM NAME Tap on the current Program name Use the keyboard to modify the name ...

Страница 6: ...xt to that day Once complete push Save Schedule to return to Program Management SETTING WATER BUDGET Use the Water Budget function to adjust run times for seasonal conditions without having to change your programmed run times Push on the current water budget This will open the selection screen Use the scrollable list to find and select your desired water budget Example If you want your run times t...

Страница 7: ...he time display area and the Stations Duration window will come up To set the run time tap on the time showing on the right side of the desired Station you wish to modify The time dial will come up Scroll the time to the desired run time then tap DONE 11 12 SETTING ADDITIONAL START TIMES You can then repeat this to set Start Time 2 If more start times are required push the icon at the top right to...

Страница 8: ...ntroller it will give you the option to DON T SAVE This allows you to back out without saving any changes you made SAVE Saves your changes but keeps you in the Program Management Screen SEND Saves your changes sends them to the controller and exits you from the Program Management Screen Programs Not Sent DON T SAVE SAVE SEND 13 The other way to save your changes is to simply hit the back arrow in ...

Страница 9: ...u can set the controller to have a PIN code for security You can also de register a controller or remove a controller from this account GEOLOCATION To geolocate a controller simply tap on the map icon in the top right corner of the controller s home page MY LOCATION will start the Pin in your current location If you need to move the PIN location simply drag it on the map to where you need it to be...

Страница 10: ...et the security key the passcode set on the device disconnect the battery or batteries Use one of the batteries to make a reverse connection on the battery terminal positive to negative Hold this connection for 5 seconds Launch the App and Add the device to your account by following steps 1 5 Go to the Edit screen and type in a new security key ACCESSING THE APP FROM A DESKTOP OR LAPTOP While the ...

Страница 11: ...m use of the product or incidental or consequential damages to other parts of any installation of which this product is part The warranty shall not apply to any equipment which is found to have been improperly installed set up or used in any way not in accordance with the instructions supplied with this equipment or to have been modified repaired or altered in any way without the expressed consent...

Отзывы: