Klein + Hummel
Operating Manual KPA Series
English
19
Hardware monitor
In this screen you can view some information about the system parameters:
•
PWRBSCH1 - PWRBSCH2 amplifier power supply voltages channel 1-2
•
VAUX internal auxiliary voltages
if you push the ”more” button, you can view the others parameters:
•
+5VAN auxiliary analog voltage
•
VEXT external remote control voltage
•
VAUX if the ”OK” written is displayed, auxiliary voltages of power supply are correct.
•
IGBTCONV if the ”OK” written is displayed, the DC/DC converter monitor function properly
•
192KHZ if the ”OK” written is displayed, the frequency system clock is right
LCD contrast
In this screen you can set the contrast of the LCD display by pushing the +/- buttons (see
figure 29
).
figure 29
Set keylock code
In this screen you can insert the numeric key to unlock the settings; the same screen appears when the ”unlock”
button in the main screen is pressed. There is a universal key to unlock the settings: this is 270156.
figure 30
Menu locking
In addition to the basic pushbutton locking function, a new menu locking strategy was introduced. There are three
levels of locking: All locked, Allow safe, Allow all.
All locked: only the menus for displaying infos are enabled, the other are hidden. Presets cannot be loaded.
Allow safe: user can change from Analog input to AES3 input, always with DSP into the signal path. Some common
DSP parameters can be changed (AES3 gain trim, main delay, DSP input selection)*.
Only local presets can be recalled, and they should be all safe for the speaker system connected to that amplifier
(example: HF driver 3 dB, HF driver 0 dB, HF 3 dB).
Allow all: all settings menus are enabled. User can recall presets from either local memory or smartcard.
Contra st
6
000000
Set keylock Code
^