background image

User information   

          

 

                                      Angled mincer WW 130/160 

 

WWD130 

10.06.2022

 

Speicherdatum 10.06.2022 11:53:00

 

Seite 8

 

2.7 

Installation of the machine 

Installation and commissioning should be done by K+G WETTER 
customer service or a qualified contractor. The meat mincer is 
delivered completely assembled and ready for operation. At the 
location, the machine can be transported on a lift cart or a fork lift. 
Before setting the machine down, remove the wooden transport 
pieces and screw in the 4 machine feet. The gross weight of the 
meat mincer is 810 kg. 
To level the meat mincer, place a spirit level on the funnel and level 
the machine by adjusting the height of the rubber feet. Finally, lock 
the feet in place with the lock nuts. 

2.8 

Electrical connection 

The machine may only be connected to the mains by a 
qualified electrician.

 

The machine is delivered with a 4 m cable. The electrical equipment 
is in accordance with EN 60 204-1 and is depicted in the enclosed 
circuit diagram. The electrical connection should be carried out 
according to the technical specifications on the identification plate 
and in Chapter 1. The cable diameter must be determined 
according to the fuse in the cable. Neutralisation, earthing, residual 
current or overcurrent release protection should be installed 
according to the conditions on site.  

 

2.9 

Tests before commissioning  

The following tests are required before commissioning: 

Checking mains voltage and frequency 

Check the mains voltage and frequency by comparing the 
indications on the electric company counter with the indications on 
the machine plate. Inform customer service if they do not 
correspond. 
The voltage variations may not be larger than + 10% and - 5%. 
Malfunctions and premature wear may be expected with larger 
deviations. The guarantee provisions do not apply in this case. 

The rotational direction of the worm must be checked as follows: 

- Switch on meat mincer without cutter assembly or 

worm using the the key. 

- The worm drive pin must turn in the 

counterclockwise direction when viewed through the 
discharge guard and the worm housing.

 

- If the rotational direction of the worm is incorrect, the 

poles of the conncting line must be reversed by a qualified 
electrician. 

- The prescribed daily safety inspection must also be carried out 

(see chapter 3.3). 

 

2.10  Area of application 

 

 

Содержание 400/1139

Страница 1: ...User information Angled mincer WW 130 Machine number 400 1139...

Страница 2: ...liged to allow only those persons to operate the machine who are instructed in the operation of the machine and who are familiar with the basic regulations concerning safety at work and accident preve...

Страница 3: ...inspection and maintenance intervals is also part of proper use Take good care of your meat mincer Observe the cleaning and maintenance information and the instructions for cutter assembly changing O...

Страница 4: ...ioning 9 3 Safety measures 10 3 1 Safety devices and their safety functions 10 3 1 1 Main switch 10 3 1 2 Covering 10 3 1 3 Protective grating 10 3 1 4 Discharge guard 10 3 1 5 Worm ejector 10 3 1 6 M...

Страница 5: ...cleaning and disinfection 19 6 Preventative maintenance and repair work 21 6 1 Resharpening cutter assembly 21 6 2 Lubrication 21 6 3 J hrliche vorbeugende Instandhaltungsarbeiten Fehler Textmarke ni...

Страница 6: ...ter Diameter of perforated plate 130 mm Working worm speed 180 360 U min Feed worm speed 19 38 U min Machine Width 1370 mm Depth 1080 mm Height 1290 mm Weight 810 kg Noise level 70 dBA Contact water p...

Страница 7: ...d disposal provisions emission and environmental protection provisions 2 3 Instructions for handling transport and storage The machine is delivered with installed worm and cutter assembly It must be s...

Страница 8: ...ations on the identification plate and in Chapter 1 The cable diameter must be determined according to the fuse in the cable Neutralisation earthing residual current or overcurrent release protection...

Страница 9: ...chine is not however equipped with devices for preventing infections which could emanate from the processed product Possibly additional measures will be necessary 2 10 3 Prohibited use The meat mincer...

Страница 10: ...using and screwed down doors and covers Before the doors or cover are opened the main switch must be set to 0 The machine may only be operated with a fully enclosed housing 3 1 3 Protective grating Th...

Страница 11: ...User information Angled mincer WW 130 160 WWD130 10 06 2022 Speicherdatum 10 06 2022 11 53 00 Seite 11 the cutter assembly forward for removal after the cap nut has been removed...

Страница 12: ...out of operation until the malfunction is corrected It is prohibited to operate the meat mincer without a functioning protective grid The run on time after the machine is switched off is ca 2 seconds...

Страница 13: ...53 00 Seite 13 4 Working with the angled mincer 4 1 Description of the angled mincer 1 2 3 4 5 6 7 8 9 10 11 Fig 1 1 Protective grating 7 Main switch 2 Funnel 8 Discharge guard 3 Feed worm 9 Locking...

Страница 14: ...fe pin Fig 2 No 17 Insert the working worm with the 4 sided carrier piece Fig 2 No 15 slowly while rotating When the worm contacts the collar rotate the worm until the 4 sided carrier piece slides int...

Страница 15: ...ing cutter assembly Single cutter assembly Double cutter assembly for fresh meat only Fig 2 No Description Pieces No Description Pieces 1 Precutter 1 10 Insertion ring long 1 2 Knife 4 5 or 6 wing 2 1...

Страница 16: ...II Fig 3 Pos 2 as desired The feed worm is always switched on with the working worm The working worm is switched off with the 0 button Fig 3 Pos 3 For reasons of safety the meat mincer can only be sw...

Страница 17: ...The discharge channels of the sorting knife are designed for this diameter Construction of the sorting cutter assembly for 2 and 3 mm grain Precutter Knife Perforated plate 8 or 13 mm Sorting knife P...

Страница 18: ...erruptions e g refilling meat Switch off all functions by switching the 0 button to red Fig 3 Pos 3 Switch back on after work interruptions with button I or II Fig 3 Pos 1 or 2 Do not allow meat mince...

Страница 19: ...h a high pressure cleaner Procedure for cleaning Prepare the meat mincer as described in chapter 5 1 Preclean with brush and water jet or clean all parts thoroughly with brush and luke warm water or c...

Страница 20: ...supply R 1 2 see picture 5 and rinse whith potable water for about 15 20 seconts Before commissioning rinse off the entire meat mincer with potable water from a hose Rinse out filling openings and wo...

Страница 21: ...y A sharp cutter assembly is absolutely necessary to achieve the best results Have resharpening done by qualified personnel only The K G WETTER customer service department and the customer service dep...

Страница 22: ...the motor has cooled down Check mains connection fuse and replace or switch back on if necessary Thermal protection device is activated Allow motor to cool down The engine does not pull through corre...