7. INCLUDED ACCESSORIES

KT2

KT2C

KTL2

KTL2C

• 

1 x M5 turned steel thumb nut 

• 

1 x 4-pin Phoenix connector

• 

1 x Double threaded screw

• 

1 x Nylon anchor 6x30mm

• 

1 x Jumper cable

• 

1 x 4-pin Phoenix connector

• 

1 x Jumper cable

• 

1 x M5 turned steel thumb nut 

• 

2 x 4-pin Phoenix connector

• 

1 x Double threaded screw

• 

1 x Nylon anchor 6x30mm

• 

1 x Jumper cable

• 

2 x 4-pin Phoenix connector

• 

1 x Jumper cable

Weight Table

KT2

KT2C

KTL2

KTL2C

Kg

0.56

0.67

0.54

0.65

lb

1.23

1.48

1.19

1.43

3,7in

95mm

4,6in

117,5mm

1,8in

46,9mm

4,8in 121mm

4,8in

122,6mm

2,9in

74,2mm

4,9in

125mm

4,7in

118,75mm

4,6in

116,75mm

4,0in 102mm

8. PHYSICAL

Содержание Tornado KT2-HV

Страница 1: ...2 HV KT2C KT2C HV KTL2 KTL2 HV KTL2C KTL2C HV USER GUIDE English KT2 KT2 HV KT2C KT2C HV KTL2 KTL2 HV KTL2C KTL2C HV Tornado NEW All Tornado models are also available in a 70V version See Paragraph 9...

Страница 2: ...OPTIONAL FEATURE 4 4 APPLICATIONS 4 5 SAFETY INFORMATION 5 6 UNPACKING 5 7 INCLUDED ACCESSORIES 6 8 PHYSICAL 6 9 REAR PANEL AND WIRING 7 9 1 70V VERSION 8 10 INSTALLATION 9 11 ACCESSORIES 10 11 1 KA1...

Страница 3: ...ation please observe the respective country specific regulations WEEE Please dispose of this product at the end of its operational lifetime by bringing it to your local collection point or recycling c...

Страница 4: ...can be controlled thanks the wide range of K array accessories via DMX or by remote With its ability to effortlessly reproduce speech music and lighting it is an excellent choice for fixed application...

Страница 5: ...o naked flame sources such as lighted candles should be placed near the device Do not attempt to disassemble the unit The unit contains no user serviceable parts Repairs should be performed only by fa...

Страница 6: ...or 1 x Jumper cable 1 x M5 turned steel thumb nut 2 x 4 pin Phoenix connector 1 x Double threaded screw 1 x Nylon anchor 6x30mm 1 x Jumper cable 2 x 4 pin Phoenix connector 1 x Jumper cable Weight Tab...

Страница 7: ...A10 or a KA10 10 amplifier the 8 configuration must be used with a KA1 1 amplifier 2 to pin of the Amp 2 bridged to 1 1 bridged to 2 1 to pin of the Amp 2 1 parallel to pin of the Amp 2 1 parallel to...

Страница 8: ...ts by two bridged KA24 amplifier channels 70V Version Wiring with KA24 2 not connected 2 not connected 1 to 1 pin of the Amp 1 to 2 pin of the Amp 2 2 1 1 1 2 1 2 2 2 1 1 1 2 1 2 KA24 Bridge Mode KA84...

Страница 9: ...Tornado 9 Ver 2 7 10 INSTALLATION KT2 KTL2 KT2C KTL2C 6 mm 105 mm 0 24 4 13 3 4 5 6 plaster board or ceiling tile 1 2...

Страница 10: ...speech applications K AL120 120 W DIN rail power supply for up to 5 KA1 T2H full power or up to 10 KA1 T2H in background music or speech applications and for K RGBDMX KRGBREM RGB LED controller for K...

Страница 11: ...Tornado 11 Ver 2 7 11 1 KA1 T2H WIRING 2 2 1 1 R G B V...

Страница 12: ...send the unit in for service In this instance you will be provided with an RA Return Authorization number which should be included on all shipping documents and correspondence regarding the repair Sh...

Страница 13: ...90 CROSSOVER Type External Crossover required Frequency 150 Hz 24 dB oct suggested minimum TRANSDUCERS Full range 2 Neodymium magnet woofer with 2 x 0 8 voice coils POWER AUDIO INPUT Connector 4 pin...

Страница 14: ...kHz 1 W 0 100 Notes for data 1 EIAJ Test Standard 1 kHz 1 THD New materials and design are introduced into existing products without previous notice Present systems may differ in some respects from th...

Страница 15: ...ystem K array 0068 CPR xxx 2017 EN 54 24 2008 Loudspeaker for voice alrm systems for fire detection and fire alarms systems for buildings KT2 TYPE B K array 0068 CPR xxx 2017 EN 54 24 2008 Loudspeaker...

Отзывы: