8. AMPLIFIER
8.1 AC POWER CONNECTOR
8.2 VOLTAGE REQUIREMENT
8.3 CURRENT REQUIREMENT
The amplifier module and the rest of the audio equipment connected to it (mixing
consoles, processors, etc.) must be connected to the AC power distribution in a
proper way, preserving AC line polarity and connecting earth ground such that all
grounding points are connected to a single node or common point using the same
cable gauge as the neutral and line(s) cables. Bad grounding connections between
speakers and the rest of the audio system may produce noise, hum and/or serious
damage to the input/output stages in the system’s electronic equipment.
Before applying AC to any K-array self-powered speaker, be sure
that the voltage potential difference between neutral and earth
ground is less than 5 VAC.
KL21ma operates safely and without audio discontinuity if the AC voltage
stays within 85 and 270V, at 50 or 60 Hz.
The device is set by default to be connected to 230V AC Power.
Verify that your mains connection is capable to satisfies the power ratings of
the device.
CAUTION
Connecting the system to an AC power mains with a
voltage exceeding 270V will cause significant damage to
the device and create a serious risk for users!
The KL12ma presents a dynamic load to the AC mains, which causes the amount of
current to fluctuate between quiet and loud operating levels. Since different cables
and circuit breakers heat up at varying rates, it is essential to understand the types of
current ratings and how they correspond to circuit breaker and cable specifications.
The maximum continuous RMS current is the maximum RMS current in a period of
at least ten seconds. It is used to calculate the temperature increase in cables, which
is used to select cables that conform to electrical code standards. It is also used to
select the cable size and gauge, and the rating for slow-reacting thermal breakers.
The maximum burst RMS current is the maximum RMS current in a period of ap-
proximately one second. It is used to select the rating for magnetic breakers. The
maximum instantaneous peak current during burst is used to select the rating for fast
reacting magnetic breakers.
Содержание KR400S
Страница 1: ...USER MANUAL english version KR400S PRELIMINARY ...
Страница 2: ......
Страница 3: ......
Страница 4: ...PRELIMINARY ...
Страница 7: ...PRELIMINARY ...
Страница 17: ...17 PRELIMINARY KR400S 9 SYSTEM CONFIGURATION ON THE FLOOR ...
Страница 18: ...18 PRELIMINARY KR400S ...
Страница 19: ...19 PRELIMINARY KR400S A ...
Страница 20: ...20 PRELIMINARY KR400S Speakon power OUT ...
Страница 22: ...22 PRELIMINARY KR400S ...
Страница 23: ...23 PRELIMINARY KR400S ...
Страница 24: ...24 PRELIMINARY KR400S ...
Страница 25: ...25 PRELIMINARY KR400S 10 HANGING INSTALLATION INSTRUCTIONS ...
Страница 26: ...26 PRELIMINARY KR400S ...
Страница 27: ...27 PRELIMINARY KR400S 17 5 1 7 5 Set to max 5 for the three upper frames ...
Страница 35: ...35 PRELIMINARY KR400S 6 2 It is possible to assign names to the groups by simply writing in the fields ...
Страница 40: ...40 PRELIMINARY KR400S eaC 6Sub 0 20 50 1K 2K 5K 10K 20K 100 200 500 3 3 6 9 12 6 9 12 ...