LED chart

In the rear panel, the input signal monitor LED and the output 
signal  monitor  LED  blink  according  to  the  presence  of  audio 

signal at any input or output channel respectively. The input 

and output signal monitor LEDs light on orange when the DSP is 

limiting the signal level.

Front Panel

A. 

Input signal monitor LED

B. 

Output signal monitor LED

C. 

Status LED

D. 

Standby button

AC mains supply

The AC Main connection is made via the provided power cord:

1. 

insert the powerCon TRUE flying 

connector into the inlet and then 
rotate it clockwise;

2.  connect the power plug of the 

power cord to a mains socket 
outlet.

Once  properly  plugged,  the  amplifier  power  up:  the  front  and 
back LEDs light on.
In order to set the amplifier unit in standby mode, keep pressed 
the  button  on  the  front  panel  for  2 
seconds.  Keep  pressed  the  button 

for 2 seconds to wake up the 

amplifier from standby mode.

The  powerCon  TRUE  link  (AC  mains  out)  connector  allows  to 

distribute the AC main power to other units according to their 
power consumption. Please don’t exceed the limits stated on 
the next tables.

Status LED

Color

Mode

Description

orange

solid

DSP software is loading

green

solid

System ready

blue

solid

User command: system identification

purple

flashing

Network parameters reset

Power 

consumption* 

Max number of cascade 

powered equal units 

Kommander-KA18

300 W

6x KA18

Kommander-KA28

800 W

2x KA28

Kommander-KA68

1200 W

2x KA28

Kommander-KA208

1200 W

-

* Power Consumption at 4 Ω load, Pink noise, 1/8 rated power.

Power 

consumption* 

Max number of cascade 

powered equal units 

Kommander-KA14 I

400 W

4x KA14 I

Kommander-KA34

600 W

4x KA34

Kommander-KA104

1200 W

2x KA104

click!

A B C D

Содержание Kommander-KA

Страница 1: ...USER GUIDE 20230206 2RU Digital Processing Multi Channel Amplifiers Kommander KA KA18 KA28 KA68 KA208 KA14 KA34 KA104...

Страница 2: ...Kommander KA User Guide 2 This page intentionally left blank...

Страница 3: ...damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped CAUTION These servicing inst...

Страница 4: ...e equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help This device complies with FCC radiati...

Страница 5: ...te Connectivity 13 Connectivity Reset 13 K array Connect Mobile App 14 Connecting To The Built In Hot Spot 14 Embedded Web App 15 Dashboard 15 USB Media Player 15 DanteReady streamer 15 Device preset...

Страница 6: ...Kommander KA User Guide 6 This page intentionally left blank...

Страница 7: ...owerful DSPs and Class D amp modules that extend the sound experience through intelligent sound processing that can adapt to any context Each amplifier of the Kommander KA line is fully loaded on boar...

Страница 8: ...e product A 1x Amplifier unit model and version shall be one from the following list Kommander KA14 I Kommander KA18 Kommander KA28 Kommander KA34 Kommander KA68 Kommander KA104 Kommander KA208 B 2x R...

Страница 9: ...Introduction The Kommander KA amplifiers are available in two versions 4 channel units and 8 channel units Both versions implement multichannel free routing and DSP with Grouping Input EQ Output EQ L...

Страница 10: ...the front panel In rack mount installation leave one rack unit empty every three installed amplifiers to guarantee adequate air flow 4 channel Amplifier Rear Panel 1 Status LED 2 Reset button 3 4x XL...

Страница 11: ...plifier unit in standby mode keep pressed the button on the front panel for 2 seconds Keep pressed the button for 2 seconds to wake up the amplifier from standby mode The powerCon TRUE link AC mains o...

Страница 12: ...ng per channel at minimum load Kommander KA14 I 2 600 W 2 Kommander KA34 4 750 W 4 Kommander KA104 4 2500 W 4 Kommander KA18 4 150 W 4 Kommander KA28 2 600 W 2 Kommander KA68 4 750 W 4 Kommander KA208...

Страница 13: ...ice or desktop PC MAC K array Connect mobile app K array Connect is the mobile app that allows to direct manage and control a Kommander KA amplifier with a mobile device smartphone or tablet wireless...

Страница 14: ...order to lanch the embedded web app In case you need to connect manually connect to the amplifier s hot spot the default password is the device serial number e g K142AN0006 case sensitive List of avai...

Страница 15: ...ameters USB Media Player DanteReady streamer K array devices incorporate Dante as an optional software implemented solution giving the user to get immediate no fuss connectivity over IP on demand The...

Страница 16: ...nnected in parallel to the amplifier output connector 6 Select the matching loudspeaker i e the subwoofer used in the actual loudspeaker configuration eg the Truffle KTR26 matching the Vyper KV25II or...

Страница 17: ...tinations columns INPATCH 4 channel unit only The input patch tab allows to address the input connections and the input streamer media player to the four amplifier s input channels The signal managed...

Страница 18: ...nually the QR Code will change accordingly When set as CLIENT enter the data of the WiFi LAN in order to connect the unit to that network The power switch allows to toggle on and off the WiFi Ethernet...

Страница 19: ...d save the update file with extension mender into the update folder on the USB drive E Plug the USB drive to a free USB port on the amplifier rear panel F If not already operating switch on the Komman...

Страница 20: ...f line with virtual devices or on line with real active loudspeakers and amplifiers connected over the same Ethernet network The K framework3 allows you to start designing the PA system off line and s...

Страница 21: ...amework3 finds two or more devices with the wrong ID a dialog window appears where unique IDs can be assigned to the units 5 Once discovered the real units are shown in the left columns following the...

Страница 22: ...this instance you will be provided with an RA Return Authorization number which should be included on all shipping documents and correspondence regarding the repair Shipping charges are the responsib...

Страница 23: ...OUTPUT VOLUMES LIMITER INPUT EQ FACTORY PRESET MATRIX INPUT VOLUMES Output CH1 Output CH4 Output CH6 Output CH8 Output CH3 Output CH5 Output CH7 Output CH2 XLR 08 XLR 07 XLR 06 XLR 05 XLR 04 XLR 03 XL...

Страница 24: ...matrix delay full parametric IIR filters Peaking Shelving Hi Lo pass Hi Lo Butterworth On board preset Remote monitoring Remote control Wi Fi dedicated APP K framework3 via wired Ethernet connection...

Страница 25: ...ers Peaking Shelving Hi Lo pass Hi Lo Butterworth On board preset Remote monitoring Remote control Wi Fi dedicated APP K framework3 via wired Ethernet connection MAINS Operating Range 100 240V AC 50 6...

Страница 26: ...Kommander KA User Guide 26 This page intentionally left blank...

Страница 27: ...Kommander KA User Guide 27 This page intentionally left blank...

Страница 28: ...Designed and Made in Italy K ARRAY surl Via P Romagnoli 17 50038 Scarperia e San Piero Firenze Italy ph 39 055 84 87 222 info k array com www k array com...

Отзывы: