Страница 3: ...s RISK of electric schock K array declares that this device is in compliance with the applicable CE standards and regulations Before putting the device into operation please observe the respect ive count ry specific regulations WEEE Please dispose of this product at the end of its operational lifetime by bringing it to your local collection point or recycling centre for such equipment This device ...

Страница 4: ......

Страница 5: ...MPLIFIER 12 8 1 AC POWER CONNECTOR 12 8 2 VOLTAGE REQUIREMENT 12 8 3 CURRENT REQUIREMENT 12 8 4 REAR PANEL 13 8 5 POWER CONNECTORS WIRING 14 8 6 AUDIO INPUT CONNECTORS WIRING 14 8 7 AMPLIFICATION AND PROTECTION CIRCUITRY 15 8 8 DSP 15 9 SERVICE 18 10 DISPERSION GRAPHS 19 11 KN6 TECHNICAL DETAILS 20 12 KN10 TECHNICAL DETAILS 21 ...

Страница 6: ......

Страница 7: ...dymium cone speakers with 2 5 voice coils for low mid frequencies The mid high frequency section employs three 1 voice coil Neodymium compression drivers The transducers are optimized with on board DSP pre sets KN6 is designed to easily integrate with KN10s selfpowered subwoofer The KN10s subwoofer module employs two 10 transducers with Neodymium magnet structure and suspensions engineered for max...

Страница 8: ...raysystems arewarrantedagainstmanufacturingdefectsinmaterialsorcraftsmanship over a period of 2 years from the date of original purchase During the warranty period K array will at it s discretion either repair or replace products which prove to be defective provided that the product is returned in its original packaging shipping prepaid to an authorized K array service agent or distributor K array...

Страница 9: ...of malfunction which in turn can cause heat to generate and result in a fire Connect the power supply only to an appropriate power adapter Do not install the speaker in wet or humid locations without using weather protection Do not allow water or any foreign object to get inside the speaker Do not put objects containing liquid on or near the unit To reduce the risk of overheating the amplifier avo...

Страница 10: ...10 rev A KN6 KN10S 7 PHYSICAL 50 5 cm 50 5 cm 19 cm 19 cm 17 5 cm 17 5 cm 3 5 cm 3 5 cm 19 88 19 88 7 48 7 48 6 89 6 89 1 38 1 38 weight 9 kg 19 84 lbs KN6 ...

Страница 11: ...11 rev A KN6 KN10S 50 5 cm 50 5 cm 28 cm 33 5 cm 33 5 cm 33 5 cm 3 5 cm 3 5 cm 3 5 cm 19 88 19 88 11 02 13 19 13 19 13 19 1 38 1 38 1 38 weight 17 kg 37 48 lbs KN10S ...

Страница 12: ... operating window from 90 V to 260 V Check the voltage before connecting the amplifier to the AC power A higher voltage could seriously damage the device The KN6 KN10S presents a dynamic load to the AC mains which causes the amount of current to fluctuate between quiet and loud operating levels Since different cables and circuit breakers heat up at varying rates it is essential to understand the t...

Страница 13: ...to prevent peak voltage drops at the service entry 140VA 10 sec 700VA 1 sec autorange KN6 KN10S max continuous apparent power VA 8 4 REAR PANEL 1 2 5 6 7 8 9 10 14 13 12 11 3 4 1 Power connector IN 2 Power connector OUT max 15A 3 Preset selector press one to change 10 sec to store 4 Audio INPUT 5 Parallel audio OUTPUT 6 Indicator of proper operating 7 Indicator of signal clip INPUT 8 Indicator of ...

Страница 14: ...e the following wiring diagrams The Audio section includes a female balanced XLR connector and a male XLR connector wired in parallel Thanks to these connectors it is possible to feed a module and to send the same signal to another one through the LINK connector It is possible to connect till 30 different modules in parallel on the same balanced line with a source of 600 ohm output impedance A Lev...

Страница 15: ...miter The Clip limiter the average Power limiter and the High Frequency limiter reduce the risk of damaging the components of the speakers A Peak Current Shut Down acts as output stage switching process inhibition that resets itself after 2 seconds The tripping point is at 35A A temperature protection acts reducing the output stage gain above temperature level of 85 temperature on output power dev...

Страница 16: ...A KN6 KN10S 0 20 50 1K 2K 5K 10K 20K 100 200 500 3 3 6 9 12 6 9 12 KN6 narrow KN6 wide 0 20 50 1K 2K 5K 10K 20K 100 200 500 3 3 6 9 12 6 9 12 KN6 narrow MD KN6 wide MD 10 130 LINE ARRAY POINT SOURCE Spot Flood ...

Страница 17: ...0K 100 200 500 3 3 6 9 12 6 9 12 KN10S 0 3 3 6 9 12 6 9 12 KN10S 150Hz KN10S 150Hz EXT KN10S EXT 0 20 50 1K 2K 5K 10K 20K 100 200 500 3 3 6 9 12 6 9 12 0 20 20 50 50 1K 1K 2K 2K 5K 5K 10K 10K 20 20 K K 100 100 200 200 500 500 3 3 6 9 12 6 9 12 ...

Страница 18: ...e 4 You will be given an RA Return Authorization number for job tracking Refer to this number on shipping materials and in all correspondence concerning the repair Shipping charges are the responsibility of the purchaser Any attempt to modify or replace components of the device will invalidate your warranty Service must be performed by an authorized K array service center Cleaning Clean the produc...

Страница 19: ...RTICAL KN6 KN6 WIDE mode 8 KHz 4 KHz 1 KHz 500 Hz 250 Hz 8 KHz 4 KHz 1 KHz 500 Hz 250 Hz 10 DISPERSION GRAPHS IN HORIZONTAL POSITION 90 120 60 30 30 60 150 90 180 150 120 0 front back 90 120 60 30 30 60 150 90 180 150 120 0 front back ...

Страница 20: ...PIN1 ground PIN2 hot PIN3 cold Power Input Connectors 1 x 3 pin PowerCon Amplifiers Type 2 x 250W class D amplifier channel DSP controlled 2 x 20W class A B amplifier channel Power woofer 350 350 Watt1 Power driver 2 x 40 Watt1 Protection Dynamic limiter over current over temp short circuits AC power Operating range 85 270 Vac 50 60Hz autorange Max continuous and burst current 140VA 10 sec 700VA 1...

Страница 21: ...LR Wiring PIN1 ground PIN2 hot PIN3 cold Power Input Connector 1 x PowerCon Amplifiers Type 1 module class D DSP controlled Power woofer 350 350 Watt1 Protection Dynamic limiter over current over temp short circuits AC power Operating range 85 270 Vac 50 60Hz autorange Max continuous and burst current 140VA 10 sec 700VA 1 sec autorange Physical Dimensions 50 5 x 33 5 x 28 cm 19 88 x 13 19 x 11 02 ...

Страница 22: ...eserves the right to make modifications without prior notice APPROVAL WEEE K array declares that this device is in compliance with the applicable CE standards and regulations Before putting the device into operation please observe the respect ive count ry specific regulations Please dispose of this product at the end of its operational lifetime by bringing it to your local collection point or recy...