1.1 PXI-93518 Overview

1.1.1 What is the PXI-93518

PXI-93518 is an eight ports serial communication module, compatible with RS-422,
RS-485 and RS-232 standards, with fast transient voltage suppression protection
circuit. This protector can effectively suppress lightning and ESD, provide 600W
lightning surge protection power for each line, as well as surge voltage and transient
overvoltage generated on the line for various reasons, and the very small inter pole
capacitance ensures the high-speed transmission of RS-422 / RS-485 / RS-232
interface.

1.1.2 PXI-93518 Features

Eight RS-422 / 485 / 232 communication ports

Baudrate, data bit length, stop bit length (1 or 2 stop bits) and parity mode can
be set

Baud rate:
1. RS-422 and RS-485 support up to 921.6k bps;
2. RS-232 supports up to 115,200 bps.

Receiving circuit with pull-down resistor

Standard serial port operation mode

All ports adopt photoelectric isolation and ± 15kV surge protection

120Ω terminal resistance matching

Operation System Compatibility: Windows 7/ 10

Operating temperature: -40

℃~

+85

Relative Humidity: 0

90%

Содержание PXI-93518

Страница 1: ...PXI 93518 8 Ports Serial Communication Modules User s Manual User Manual Version V1 0 0 Revision Date Nov 10 2021...

Страница 2: ...uct or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright All rights are reserved No part of this manual may be repr...

Страница 3: ...hould you require any service or assistance SHANGHAI JYTEK CO LTD Web Site Sales Service Telephone No http www jytek com service jytek com 86 21 50475899 Fax No Mailing Address 86 21 50475899 300 Fang...

Страница 4: ...1 Windows 7 Installation 7 Figure 1 RS 422 Functional Structure 2 Figure 2 RS 485 Functional Structure 2 Figure 3 RS 232 Functional Structure 3 Figure 4 Connector DB62 5 Figure 5 Device Manager 7 Figu...

Страница 5: ...for various reasons and the very small inter pole capacitance ensures the high speed transmission of RS 422 RS 485 RS 232 interface 1 1 2 PXI 93518 Features Eight RS 422 485 232 communication ports Ba...

Страница 6: ...PXI 93518 jytek com 2 Figure 1 RS 422 Functional Structure Figure 2 RS 485 Functional Structure...

Страница 7: ...nnector Pin Assignment DB62 female connector pin assignment for the PXI 93518 Pin RS 232 RS 422 RS 485 Port 3 OUT1 A1 Port1 2 OUT1 B1 50 IN1 49 IN1 26 TX1 25 RX1 54 GND 5 OUT2 A2 Port2 4 OUT2 B2 48 IN...

Страница 8: ...ND 14 OUT5 A5 Port5 13 OUT5 B5 62 IN5 61 IN5 38 TX5 37 RX5 12 GND 16 OUT6 A6 Port6 15 OUT6 B6 60 IN6 59 IN6 36 TX6 35 RX6 11 GND 19 OUT7 A7 Port7 18 OUT7 B7 58 IN7 57 IN7 42 TX7 41 RX7 6 GND 21 OUT8 A...

Страница 9: ...N 1 8 Receive Data Negative RS 485 A 1 8 Data Signal Positive B 1 8 Data Signal Negative Table 2 Notes to Legend in the Pin Definitions Figure 4 Connector DB62 2 Installation This chapter describes th...

Страница 10: ...amages on the module before processing After opening the module carton remove the system module and place it only on a grounded anti static surface component side up Again inspect the module for damag...

Страница 11: ...card which is assigned by system BIOS The address assignment is done on a board by board basis for all serial communication cards in the system 2 5 Software Installation 2 5 1 Windows 7 Installation...

Страница 12: ...ftware 3 Select the Browse your computer for driver software Figure 7 Find Driver Software 4 When prompted for the path specify the drive and directory where the new driver for the card installed Choo...

Страница 13: ...PXI 93518 jytek com 9 Figure 8 Select Driver Software 5 Follow the configuration dialog boxes to install the driver Figure 9 Driver Updated Successfully...

Страница 14: ...ultifunction device Use the above method to update the driver for eight devices respectively Figure 10 The board be recognized 7 Now the port device are all identified Serial port number starts from t...

Страница 15: ...rt during product transportation Damage caused by fire earthquakes floods lightening pollution other acts of God and or incorrect usage of voltage transformers Damage caused by inappropriate storage e...

Отзывы: