Button & SW
RUN State
1. Oscilloscope Mode
2. Frequency Meter Mode
3. FFT Mode
Button Function Summary
For detailed documents please
visit
www.jyetech.com
Quick Use Guide
Applicable Model: 09601, 09602
DSO 096 Oscilloscope
Panel & Connectors
Mode Navigating
Vertical Sensitivity
Switch 1
Vertica l Sensitivity
Switch 2
Test
Si gnal
Output
Coupl e Select
Switch
Signal
Input
Connector
Control Buttons
USB Connector
Power
Switch
Vertical
Position
Indicator
Battery Indicator
HOLD s tate
Couple
Vertical
Sensitivity
Time Base
Vertical & Horizontal
Position Adjus tment
Trigger Mode
Trigger Level
Adjustment
Trigger Slope
Trigger
Level
Indicator
Trig Point
Indicator
Horizontal
Position
Indicator
Power
Switch
Battery
Connector
LCD
Contrast
Adjustment
Programming
Header
Oscilloscope
Mode (default)
Frequency Meter
Mode
FFT
Mode
Scroll highlight bar to functin wanted
and press [OK] button
Mode Select Menu
Hold [MODE]
for 3 seconds
Press [MODE]
Pre ss [MODE]
Functions
[VPOS]
[HPOS]
[SEC/DIV]
[MODE]
[SLOPE]
[LEVEL]
[VPOS] hold
[MODE] hold
[SLOPE] hold
[LEVEL] hold
[+]
[-]
[OK]
[OK] hold
V.Sen 1 & V.Sen 2
Couple
Select VPOS
Select HPOS
Select TIME-BASE
Select trigger mode
Select trigger slope
Select trigger level
Adjust the selected param.
Enter HOLD state
VPOS alignment
Enter Function Select menu
Turn LCD backlight on/off
Enter Setting Select menu
Turn off device
Change vertical sensitivity
Adjust the selected param.
Change couple method
Button & SW
HOLD State
Functions
[VPOS]
[HPOS]
[SEC/DIV]
[MODE]
[SLOPE]
[LEVEL]
[+]
[-]
[OK]
Select VPOS
Select HPOS
Save waveform to buffer
Select trigger mode
Display buffer
Send screen
Adjust the selected param.
Exit HOLD state
Adjust the selected param.
Button & SW
Functions
[MODE]
V.Sen 1 & V.Sen 2
Couple
Change sensitivity
Change couple method
Enter Function Select menu
Button & SW
Functions
[MODE]
V.Sen 1 & V.Sen 2
Couple
Change sensitivity
Change couple method
Enter Function Select menu
[+] or [-]
[HPOS]
Change sampling rate
Change FFT size
Rev. 02
(1K Hz 5Vpp )
(V/Div)
(Sec/Div)
Please note that button functions are mode and state dependent. The following
chartslist button functions under various modes and states.
Basic Operations
1. Powering ON/OFF the Unit
2. Setting Parameters
1 ) If battery is connect ed and external power supply ( USB) is not used setting power switch to "BATT" position
will turn t he oscilloscope on. Settin g the switch to "USB" position will turn the unit off.
2 ) If USB is connected ALWAYS keep the power switch at "USB" position and use plugg ing/unplugging to
powe r on/off the uni t.
3 ) If you un-intentionally placed t he switch a t "BATT" position while USB is conn ected you may find the unit can
not be power on no matter by the switch or by plugging in USB cable . In th is case unplug USB cable and set the
switch to " USB" position. Wait for 10 - 30 seconds or longer the n turn it on by s witch or pluggi ng in USB cable.
[Not e: This situation won't happe n if the bulit-in battery charger was disconnected. For how to dis connect
battery charger please s ee explanation below]
1 ) Vert ical -
,
, and
Sensitivity Position
Coupling
Ø
Use the top two sli de switches to set sensitiv ity
Ø
Use [VPOS] and [ + ] [ - ] but tons to change waveform vertical position
Ø
Use the bottom slide switches to s elect coupling
2 ) Horizontal -
and
Timebase
Position
Ø
Use [ Sec/Div] and [ + ] [ - ] buttons to set timebase
Ø
Use [HPOS] and [ + ] [ - ] to change waveform horizontal po sition
3 ) Trigger -
,
, and
Mode Slope
Level
Ø
Use [M ODE] and [ + ] [ - ] buttons to select trigger mode
Ø
Use [SLOPE] and [ + ] [ - ] buttons to select trigger slope
Ø
Use [LEVEL] an d [ + ] [ - ] buttons to change tr igger level