- Places where corrosive or neutral gases are present.
- At less than 20m or more than 2000m above sea level.
INFORMATION FOR INSTALLATION
- Use a monophasic AC current of 110V-120V / 60 Hz.
- Use a power supply cable with conductors with a cross-section of 2x18 AWG.
- Phase and neutral are connected without any polarity on the internal connector.
- The power wire must be at the back of the appliance and must be out of reach when the hand
dryer is screwed on the wall.
- Avoid places where the appliance could be hit by a door.
- Install the appliance on a perfectly flat wall.
- Allow for the power supply cable inlet.
- Find out the dimensions and space requirements of the product before installing.
INSTALLATION
- Remove the cover
- Insert the power wire in the hole and fix the appliance on the wall.
- Connect the power supply to the connecting block (terminals identified by the arrows ).
You must use the drilling clamp supplied with the appliance.
-
Replace the cover and fix it with the two screws and the “allen” key supplied with the appliance.
Connecting
block
Drilling
clamp