Prior to performing the following procedures, remove
the elevator base.
Remove the belt on the upper side of the loading
base assembly.
Remove the screw
R
attaching the pulley gear.
Remove the pulley gear, the gear 1, the gear 2 and
the belt respectively.
Remove the screw
S
and the load base upward.
Remove the two screws
T
and the slide gear
upward.
1.
2.
3.
4.
5.
Removing the belt / load base / slide
gear
CAUTION: When reattaching the slide gear
and the load base,
Move the slide gear toward the front until it stops
(Fig.23).
Make sure that the part
d
of the load base is out of
alignment with the switch
e
and that the gear
f
is
disengaged from the slide gear.
1.
2.
Fig.20
Fig.21
Fig.22
Fig.23
Loading base assembly
R
Belt
Pulley gear
Gear 2
Gear 1
Pulley gear
S
Load base
Loading base assembly
T
Slide gear
Slide gear
Switch e
Load base
Gear f
Part d