67
Protocol Page
This page is for changing the HTTP server port number.
This page can be used during access using
A
admin
B
.
●
Click [Advanced Settings] to display setting menu.
●
Click [Protocol].
●
Press the [OK] button to enable the new settings.
●
After changing, you will need to re-establish the connection if you are using the Internet Explorer.
Memo:
●
If Built-in Viewer is used for playback, change the HTTP port number in the setting screen of Built-in
Viewer to the same value.
A
B
C
D
Click
A
HTTP Server
Port
You can change the port number for the built-in web server of VN-X35U.
(1 to 65535: The default port number setting is 80.)
The JPEG and MPEG4 HTTP port number for the web server will also be
changed. During access to VN-X35U from the Internet Explorer, enter the
following in the Internet Explorer when the camera is in its default settings.
http://192.168.0.2
If the port number is changed to 8080, for example, enter the Internet
Explorer as follows.
http://192.168.0.2:8080
B
VISIP Protocol
For setting VSIP to On/Off.
Set to
A
On
B
if you want to use this unit from Verint's Nextiva products.
C
VISIP Server
Port
For changing the built-in VSIP number of VN-X35U.
(1 to 65535: Default value is 5510)
D
AMX Device
Discovery
Protocol
For setting AMX Device Discovery Protocol to On or Off.
Set to
A
On
B
when you are using VN-X35U on AMX's systems.
[Set values : On, Off]
Содержание VN-X35U - Network Camera
Страница 52: ...52 Setting Using Internet Explorer Alarm Page continued Setting continued E F G H I J K ...
Страница 56: ...56 Setting Using Internet Explorer Alarm Environment Page continued Setting continued C ...
Страница 82: ...82 Setting Using Internet Explorer Settings Page continued Setting continued ...
Страница 83: ...83 ...
Страница 111: ... 2008 Victor Company of Japan Limited LST0789 001A VN X35U MEGAPIXEL IP CAMERA ...