18
2.
Mount the fall-prevention wire to the base
(The fall-prevention wire is not attached)
Remove the fall-prevention wire mounting screw
of the base and mount the fall-prevention wire.
Note
:
●
Also pay careful attention to the length,
strength, wiring and material (insulation
quality) of the fall-prevention wire to be used.
●
For the fall-prevention wire, the inside
diameter of the ring section to be mounted on
the camera unit should be between
R
4.1 mm
and
R
6.5 mm, and the outside diameter
should be below
R
12 mm.
3.
Mount the fall-prevention wire to a strong
location.
Mount the fall-prevention wire to a strong
location to prevent fall.
4.
Mounting the base
Face the imaging direction mark inside the base
(
j
) in the shooting direction and mount the base.
When mounting to a wall, face the imaging
direction mark (
j
) upwards.
Use two
R
4 mm screws for mounting.
Note
:
●
When mounting to a wall, be sure to face the
imaging direction mark (
j
) upwards.
●
R
4 mm screws are not supplied. Use the
appropriate type according to the material of
the location for mounting.
●
The two attached screws (M4
⳯
8 mm) are
for mounting the base to the adapter plate.
Do not use them here.
1.
Connect the LAN cable (
2.
Connect the power cable, alarm cable and
heater cable
(
Memo
:
●
The power cable must not be connected
when PoE is used.
●
When the camera is installed with a heater
(sold separately: KA-ZH215), be sure to
connect it to AC 24 V power supply.
●
The AC 24 V power supply should conform to
the following : Class 2 only (Fou USA),
Isolated power supply only (For Europe).
3.
Wind the waterproof tape
Note
:
●
Be careful not to drop the camera when it is
removed from the base.
2
4
8 mm
2 mm
3
Fall-prevention
wire
Base
R
4 mm screw
Towards the shooting
direction
(Face upwards when
mounting to wall)
Cable connection
2
3
1
Solder or crimp
Wind the insulation tape
Wind the
waterproof tape
Power cable, alarm
cable
LAN cable
LAN cable
10BASE-T/
100BASE-
TX(PoE)
terminal