(No.MB512)1-23
4.3
Key special mode
4.4
Remocon special mode
STEP
OPERATION
MOVEMENT
FL (LCD) indication
13
12
11
10
1 2 3 4 5 6 7 8 9
6
Press +10 at 10 key of remocon.
BCA READ CHECK
0 : During BCA READ
1 : BCA READ OK
2 : BCA SEEK ERROR
3 : BCA READ ERROR
4 : SPINUP adjustment ERROR
7
Press MENU key of remocon.
Return to STEP2.
Press POWER key of main unit.
Releasr the TEST MODE.
12
Press STOP key of main unit/remocon.
Disc stop, LD-OFF.
13
Press OPEN/CLOSE key of main
unit/remocon.
Tray open/close.
14
Press PLAY key of main unit/remocon.
Disc playback.
15
C H E C K
*1 Mode toggle by press MENU key.
*2 STEP2-3 and STEP3 are only for DVD-AUDIO or VR correspondence model.
Mode name
Operation
Function
Press STOP key & PLAY key together
at TUNER AM then 9kHz step.
Tuner 9k/10k select
(U*version)
Press STOP key & PAUSE key together
at TUNER AM then 10kHz step.
Press STOP key & EJECT1 key together
at P.OFF.
TRAY LOCK
At AC off line condition, press
PLAY+POWER together and keep
condition, connect AC.
DVD TEST MODE
At AC off line condition, press
PAUSE+POWER key together and keep
condition, connect AC.
SYSTEM TEST MODE
At AC off line condition, press
STOP+PAUSE key together and keep
condition, connect AC.
AVC ROM-CORE MODE
9kHz/10kHz step select of TUNER AM band.
Into the AV compulink rom-core rewrite mode.
"Set to speaker measurement mode.At source AM, operation the
beat cut by remote controller.Other operation is as same as normal
condition.
Mode release by POWER OFF."
"Operation to TEST mode to on of DVD backend.
Operation of internal TEST MODE is refer the TEST mode."
DO the TRAY LOCK mode select. Temporaly P.ON operation, select
"LOCKED", "UNLOCKED". (Not done P.ON operation).
Transience (2sec.) indication end, and then return to P.OFF mode.
When press the EJECT key at LOCK mode, at P.OFF condition
tempraly P.ON operation and then transience (2sec.) indication
"LOCKED".
At P.ON condition, transience (2sec.) indication "LOCKED".
Mode name
CODE
Function
B330
COLD START
B331
FL all on
Preset frequency writeing
B33E
Operation
2-times input at P.OFF.
Input at P.ON.
Input at P.ON.
Version indication
"Fix by 2 time input, operation temporaly P.ON and then transience(3sec.)
indication "COLD SET".
Indication end, done the P.OFF mode.
AC to off line, operation the COLD START.B330 : remote controller press
POWER + STOP + 0 key together."
"Indication turn Syscon version - Unit version - Distination, Chip select by
transience(5 sec.).
Syscon version : "SC ## $$" (## : Sys version,$ : Sys ROM-core)
Unit version : "BE %%%% "(%%%% : Unit version)
Distination, Chip select : "$$ %%"($$ : sys distination, %% :
"P3" or "P5" or "P7")
B33E : Press remocon POWER + STOP + 10 key together."
"Rewrite preset frequency, LED on chek(each 300ms), FL all onLED on turn
: STANDBY - ILLUMI - REMOCON<VOL+> - <VOL->Volume control of key
input, keep high-speed mode until POWER OFF.
B331 : Remocon POWER + STOP + 1 key together"