Specifications

* The specifications and appearance of this unit are subject to change for purposes of improvement without prior notice.

VN-H257U

VN-H237U

Camera 
section

Image sensor

1/3-inch Square-Pixel Progressive Scan CMOS (elementary color filter)

Effective pixels

Approximately 2,120,000 pixels
1944 (H) x 1092 (V)

Minimum illuminance 
of subject

(50 %, AGC High, 1/30 s)
Color: 0.3 lx (typ.)
Black and White : 0.03 lx (typ.)

(50 %, AGC High, 1/30 s)
Color: 0.3 lx (typ.)
Black and White : 0.25 lx (typ.)

Monitor output

75 

Ω

, 1.0 Vp-p

NTSC or PAL (switch selectable)

Audio input

Input

Can connect to a microphone that has a 
plug-in power system

Reference voltage

DC 2.47 V(typ.)

Impedance

2.2 k

Ω

 (typ.)

Audio output

Line OUT (200 

Ω

, Max 1.9 Vp-p)

Network 
output

Image compression format

JPEG, H.264 High Profile, H.264 Baseline Profile, MPEG-4

Frame size

  1920 × 1080

1280 × 960
1280 × 720

640 × 480
640 × 360
320 × 240

Audio compression 
formats

μ

-Law (64 kbps), AD/DA 16 bits, 

Fs = 8 kHz, monaural

Network interface

RJ-45
100BASE-TX/10BASE-T/FULL/HALF/Auto-negotiation enabled

Alarm input

No-voltage a contact input, PNP 
open collector input, low level, latch/
momentary (500 msec or longer) (1 mA 
circuit current at low level, and 3.3 VDC 
applied voltage at high level)

Alarm output

NPN open collector-output (16 VDC safe 
excitation voltage, and 30 mA allowable 
sink current)

Alarm record

16 MB

Lens

Focal length

f = 3 mm to 9 mm

f = 2.8 to 10.5 mm

Maximum aperture ratio

F1.2 (f = 3 mm) to F2.1 (f = 9 mm)

F1.2 (f = 2.8 mm) to F2.6 (f = 10.5 mm)

Aperture range

F1.2 to F360

F1.2 to F360

Zoom ratio

3 x

3.75 x

LAN 
standards

Standards

Compliant with IEEE802.3, IEEE802.3u and IEEE802.3af

Communication 
protocol

TCP/IP, UDP/IP, FTP, ICMP, ARP, DHCP, SNTP, HTTP, SMTP, RTP, RTSP, IPv4, 
IPv6, DSCP, HTTPS, SNMP

General

Power supply voltage

AC24 V 50 Hz/ 60 Hz, or PoE (DC-48 V)

PoE(DC-48 V)

Current consumption

AC24 V 0.5 A, or PoE 150 mA (7.2 W)

120 mA

Ambient temperature

-10 °C to 50 °C (Operation)
0 °C to 40 °C (Recommended)

Ambient humidity

20 %RH to 90 %RH (without condensation)

Mass

Approx. 480 

g

Approx. 450 

g

Option (sold separately)

Ceiling mount bracket (WB-S2205)

LST1234-001D

350

83.5

46

20

10

7.7

11

7

SR4

2

111

4.5

87.5

4.5

83.5

46

4.5

4.5

External dimensions (unit: mm)

Hole in the ceiling (unit: mm)

Front of the camera

Φ

 1

11

 (camera body)

Mounting hole for a screw

Mounting hole for a screw

Φ

 30 (cable hole)

Pan adjustable 
range

Direction cables were pulled out

Mounting hole for a screw

Mounting hole 
for a screw

Cables

Troubleshooting

Symptom

Causes and Countermeasures

Images on the monitor are dark

If you connect the monitor output (RCA terminal) inside the dome cover to the test 
monitor while the monitor output cable on the bottom is connected to video recording 
equipment or another monitor, images may be dark.
Disconnect the monitor output cable from the video recording equipment or another 
monitor. Alternatively, set the terminal of either one of the equipments to “OPEN”.
After adjusting the image, restore the original condition.

Movement of network image is not 
smooth

If the monitor image output is turned ON, a lower frame rate is set for network images.
If you turned the monitor image output to OFF, set the frame rate again.
(

 “Instructios (Setting)” - “Internet Explorer Setting” - “Encoding Page”)


No monitor image is output.

The image output may be turned Off on Internet Explorer.
Check the monitor output setting.

The external mic sound is not heard.

Check the MIC connection.
Is the audio setting turned off? (

 “Instructions (Setting)” - “Audio Page”)


Lens is out of focus

Is the focus adjustment gear engaged? Check the location of the catch.

Audio cable connection

 (VN-H257U)

Alarm I/O cable connection 

(VN-H257U)

Alarm input

Connect an infrared sensor, door sensor, metal 
sensor, a manual switch or other device.

To avoid noise entering the internal circuit, enter the 
non-voltage contact signal in the Alarm IN terminal.
Do not supply voltage.
The alarm can be set to be activated during close 
contact (MAKE) or during open contact (BREAK) 
can be set from the menu.
The alarm signal should last for at least 500 msec. If 
the alarm signal is short, it may not be recognized.

Input conditions

Connect non-voltage a contact or open collector 
output circuit
(For details on how to set polarities, please refer to 
“Instructions (Setting)”.)
Low level terminal current below 1 mA
High level terminal current 3.3 V

3.3 V

1 mA

VCC

OUT

G

G

OUT

R

G

DC3.3 V

This 

camera

Input 1 or 
Input 2

(Alarm input equivalent circuit)

Sensor example (1)

Sensor example (2)

Relay switch or 
other devices



Alarm output

Connect an alarm device, indicator, lighting, buzzer or 
other device.

An alarm output signal is an open collector output. 
You can configure the menu to set the alarm to 
sound when contacts short circuit (MAKE) or 
when the contacts are open (BREAK). (Pressure 
resistance lower than 16V, 30 mA)
This terminal has different polarities. The output 
voltage at the positive terminal must always be 
higher than the output voltage at the negative 
terminal. Otherwise, the circuit may be damaged.

Output conditions

Equivalent to NPN open collector output
(For details on how to set the output logic, please 
refer to “Instructions (Setting)”.)
Safe excitation voltage: DC16 V or lower
Allowable surge current: 30 mA
Momentary (100 ms to 5000 ms) output
(For details on how to set the time, please refer to 
“Instructions (Setting)”.)

IN

R

DC12 V

G

G

This 

camera

Output 1 or 
Output 2

(Alarm output equivalent circuit)

Alarm device 

example

Note

Connect the G terminal cable of this camera to the 
GND of the alarm device.



* For connecting the Alarm I/O cable, refer to [Cabling] (

 page 2).

1

2

3

4

Cable type

Color

Signal name

1

 

Monitor output cable (Common)

2

  

Power cable 
(VN-H257U)

Red

AC 24 V

Black

AC 24 V

3

  

Alarm I/O cable
(VN-H257U)

Black

Red

INPUT 1 (ALARM)

Brown

INPUT 2 (ALARM)

Orange

OUTPUT 1 (ALARM)

Yellow

OUTPUT 2 (ALARM)

Black

GND (ALARM)

4

  

Audio cable 
(VN-H257U)

Brown

White

MIC IN

Yellow

GND (MIC IN)

Black

White

LINE OUT

Yellow

GND (LINE OUT)

Connecting the power cable to AC 24 V source

Conductor 
diameter (mm)

1.0 mm dia 
or more

1.6 mm dia 
or more

2.0 mm dia 
or more

Max cable 
distance (meters)
(Reference value)

90

240

370

Note

For safety reasons, turn on the power only after 
confirming that all the connections are completed.
Be sure to turn off the camera before connecting 
cables.
If you use both the AC 24 V power cable and the 
PoE-based LAN cable simultaneously, the camera 
may fail. Always supply power using either method.

•  To use an AC 24 V power supply, remove the factory-

installed tape from the power cable, connect to an AC 
24 V power supply, and wrap the connector with new 
insulation tape.

LAN cable

When connecting to a switching hub: 
Use a straight cable.
When connecting to a computer: 
Use a crossing cable.
A 100-meter or less length and Category-5 or higher 
grade STP (shielded) cable is recommended.

Note

The crossing cable may not be used for some 
computer models. Check the LAN specifications of 
the computer when you directly connect this unit to 
the computer.

Alarm I/O cable

A 50-meter or less length shielded cable is 
recommended.

Connect the audio cable for an audio device.
Audio cable (Brown and White) (MIC IN)

: Connect to a condenser microphone that has a plug-in power 

system, etc.

Audio cable (Black and White) (LINE OUT) : Connect to a speaker with a built-in amp, etc.

Memo

 A shielded audio cable is recommended.

* For the location to connect the audio cable, refer to [Cabling] (

 page 2).

VN-H257U/VN-H237U

EN_VN-H237_001D_Non-Mask.indb   4

EN_VN-H237_001D_Non-Mask.indb   4

5/24/2012   2:24:07 PM

5/24/2012   2:24:07 PM

Содержание Super LoLux HD VN-H237U

Страница 1: ...wer refer to the operating instructions 10 For added protection for this product during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the antenna or cable system This will prevent damage to the product due to lightning and power line surges 11 Do not allow anything to rest on the power cord Do not locate this appli...

Страница 2: ...ll out the fall prevention wire and cables from the hole the fall prevention wire and cables are not provided 3 Fasten the free end of the wire clamp with the attachment screw of the wire clamp 4 Tighten the attachment screw of the wire clamp and fix the LAN cable Securing the LAN cable Secure the LAN cable using the wire clamp 1 Loosen the attachment screw of the wire clamp until it is loose but ...

Страница 3: ...e pan rotation and tilt directions 175 100 and 80 respectively from the position aligned with the camera s shooting direction mark pan center mark and rotation center mark Be sure to hold the rotation control and adjust the rotation without holding the lens section When you mount the camera body align the shooting direction mark within the shooting range When you mount the dome cover make sure tha...

Страница 4: ...arm input Connect an infrared sensor door sensor metal sensor a manual switch or other device To avoid noise entering the internal circuit enter the non voltage contact signal in the Alarm IN terminal Do not supply voltage The alarm can be set to be activated during close contact MAKE or during open contact BREAK can be set from the menu The alarm signal should last for at least 500 msec If the al...

Отзывы: