(No.MB294)1-35
4.3
Normal initialization method
Please initialize according to the following procedures in the following case:
• Just after you upgrade the firmware.
• After you confirm the symptoms that a customer points out. First Initialize, and then confirm whether the symptoms are improved or
not.
• After servicing, before returning the main body to a customer. (Initialized main body should be returned to a customer.)
(1) Set the main body at test mode.
(2) Press "PAUSE" key of the main body.
(3) When initialization is completed, "00" and "RDS" is displayed in the FL display.
(4) After this, power switch to off and wait untill "See You" to off.
4.4
Full-initialization method
Please perform all-initialization according to the following procedures in the following case:
• Just after you exchange the pick-up.
• Just after you exchange the spindle motor.
• Just after you exchange the traverse mechanism base.
NOTE:
Please perform all-initialization when you exchange the parts above and also when you remove the parts above.
• Just after the flap adjustment of the pick-up guide shaft.
(1) Set the main body at test mode.
(2) Press and hold "F.SKIP" key of the main body for more than 1.5 seconds.
(3) When all-initialization is completed, "33" and "RDS" is displayed in the FL display.
(4) After this, power switch to off and wait untill "See You" to off.
NOTE:
After all-initialization, be sure to perform Device Key Writing.
Содержание SP-PWM508
Страница 36: ...1 36 No MB294 SECTION 5 TROUBLESHOOTING This service manual does not describe TROUBLESHOOTING ...
Страница 37: ... No MB294 1 37 ...
Страница 44: ...2 4 SHEET 3 Video input output section To System control section SHEET 2 ...
Страница 45: ...2 5 SHEET 4 SHEET 2 SHEET 2 SHEET 2 FL display section ...
Страница 46: ...2 6 SHEET 5 Audio input output section ...
Страница 47: ...2 7 SHEET 6 SHEET 2 SHEET 2 Jack section ...
Страница 53: ...2 13 SHEET 12 Amplifier section To CN121 SHEET 10 To CN122 SHEET 10 ...
Страница 59: ... M E M O ...