background image

Mounting the Camera (Continued)

m

Fall Prevention

v

Special attention is required when installing the camera to the wall or ceiling.

You should not engage in the installation work yourself. Ask a professional to do

the job, because injuries and accidents may occur if the camera falls.

v

When installing the camera on a fixer, pan/tilt unit and the like, make sure to

install it firmly using a rotation-preventive hole to prevent fall.

v

To prevent fall, connect the camera to a section with sufficient strength (ceiling

slab or channel) using a fall prevention wire.

v

Pay attention to the length, strength, routing and material (insulation properties)

of the fall prevention wire used.

v

Use the screw (M3 x 6 mm) on the back of the camera for the installation of the

fall prevention wire. Do not use a screw that is longer than 6 mm as it may

damage the internal parts.

.

.

Fall Prevention Wire

DC12V

SET

MANU

AL

SEE INSTR

UCTION

GND

AUX

ONLY 

(E TYPE

)

ISOLA

TED PO

WER

(U TYPE

)

CLASS 2 ONL

Y

MENU

OUT

VIDEO

ON

CRT

ON

OFF

AES OFF

LCD

BLC OFF

D/N A

UTO

MONIT

OR TYPE

AC24V

1

2

ADJUST

FOCUS

M3 x 6 mm

6mm

2 mm

6 mm

Note

When mounting the camera to the ceiling, ensure to wear safety glasses

to protect the eye from any falling objects.

Connection/Installation

10

Содержание SLL TK-C9300UA

Страница 1: ...K C9300U TK C9300E TK C9301EG INSTRUCTIONS For Customer Use Enter below the Serial No which is located on the body Retain this information for future reference Model No TK C9200U TK C9200E TK C9201EG Serial No TK C9300U TK C9300E TK C9301EG LST0984 001A ...

Страница 2: ...ecautions 4 Connection Installation Mounting the Lens 6 Connection 7 Mounting the Camera 9 Setting Adjustment Switch Settings 11 Adjusting the Back Focus 12 Fine tuning the Focus 13 Adjusting the Auto White Balance 14 Others Specifications 15 Introduction 2 ...

Страница 3: ...acy mask v Built in display mode CRT or LCD selectable How to read this manual Conventions and symbols Note Indicates operating precautions Memo Indicates reference data regarding limitations on functions usage and the like A Indicates a reference page or item Contents of this manual v JVC holds the copyright to this manual Any part or all of this manual may not be reproduced without prior consent...

Страница 4: ...ing so may melt the surface or cause it to fog For tough stains wipe with a neutral detergent diluted with water followed by wiping with a dry cloth m Energy Conservation v When the camera is not in use for a long time turn off the power for safety and energy conservation reasons m Copyright Protection v With the exception of the user being the copyright holder or when permission such as for dupli...

Страница 5: ...v When the white balance of this camera is set to ATW N or ATW W and depending on the conditions of the object the color tone may differ slightly from the actual color due to the principle of the automatic tracking white balance circuit This is not a malfunction v When this camera is used under high temperatures vertical stripes may appear on the screen This is a characteristic of the CCD and not ...

Страница 6: ...ow normal installation This will result in a malfunction a b 12 5 mm Flange back b Dimension a 5 5 mm or less 2 Turn the lens clockwise and mount it securely on the camera 3 In the case of a DC IRIS lens check the pin arrangement and connect the lens cable to the socket POWER IRIS 3 3 2 2 1 2 3 4 Memo v Video IRIS lens cannot be used v If the plug of the lens cable is different connect with a 4 pi...

Страница 7: ...onnection distances when 2 core VVF vinyl insulated vinyl sheath cables are used Reference value Conductor diameter mm Φ 1 0 and more Φ 1 6 and more Φ 2 0 and more Maximum connection distance DC 12 V 50 m 140 m 220 m Maximum connection distance AC 24 V 130 m 350 m 550 m Memo v If thin cables are used the resistance of the cables will be high and a significant voltage drop will occur when the camer...

Страница 8: ...noise from entering the internal circuit supply non voltage setting signal to the alarm input signal v Do not supply voltage v Using the menu you can select whether to set to alarm when the contact is short MAKE or when the contact is open BREAK v Supply such that the alarm signal stays at a minimum of 200 ms or more Otherwise the alarm signal may not be recognized AUX IN Please use a shielded cab...

Страница 9: ...h length shorter than 6 mm Do not use a screw that is longer than the specified length It may damage the internal parts m Mounting the Camera Mounting Bracket on Top of the Camera The camera mounting bracket is originally mounted at the bottom of the camera before shipment but it can also be mounted on top of the camera 1 Remove the camera mounting bracket fastening screws x2 The camera mounting b...

Страница 10: ...lab or channel using a fall prevention wire v Pay attention to the length strength routing and material insulation properties of the fall prevention wire used v Use the screw M3 x 6 mm on the back of the camera for the installation of the fall prevention wire Do not use a screw that is longer than 6 mm as it may damage the internal parts Fall Prevention Wire DC12V SET MANUAL SEE INSTRUCTION GND AU...

Страница 11: ...is to ON when shooting in backlight The subject becomes easier to see as brightness is adjusted according to the photometry area set in BLC AREA of the menu Default setting OFF C MONITOR TYPE LCD CRT Monitor Type Selector Switch Set this to LCD or CRT according to the monitor in use Default setting LCD D AES OFF ON AES Selector Switch TK C9200U TK C9200E TK C9201EG When this is set to ON automatic...

Страница 12: ...ning screw by turning it clockwise m With a Zoom Lens If the image is out of focus when zooming telephoto wide angle adjust the camera as follows 1 Loosen the back focus fastening screw by turning it anti clockwise with a screwdriver 2 Shoot some fine patterns on the subject or away from the subject 3 Zoom to the maximum telephoto position and turn the lens focus ring to adjust the focus 4 Zoom to...

Страница 13: ... screen Contours are emphasized as the iris opens 2 Shoot the subject 3 Adjust the focus of the DC IRIS lens 4 Exit the Focus Adjust mode Press any of the K H I SET MENU buttons to cancel the Focus Adjust mode The mode is also automatically deactivated after about 30 seconds SET MANUAL SEE INSTRUCTION GND AUX ONLY E TYPE ISOLATED POWER U TYPE CLASS 2 ONLY MENU OUT VIDEO ON CRT ON OFF AES OFF LCD B...

Страница 14: ... SET MANUAL SEE INSTRUCTION GND AUX ONLY E TYPE ISOLATED POWER U TYPE CLASS 2 ONLY MENU OUT VIDEO ON CRT ON OFF AES OFF LCD BLC OFF D N AUTO MONITOR TYPE DC12V AC24V 1 2 ADJUST FOCUS MENU button button SET button AWC OPERATION AWC OK adjustment completed during operation m Error display If auto white balance adjustment is not successful the following messages will appear on the monitor v AWC ERROR...

Страница 15: ... V AC 240 V 50 Hz 60 Hz TK C9201EG TK C9301EG Length of power supply cable 1 900 mm TK C9201EG TK C9301EG Current power consumption 2 3 W TK C9200U 190 mA TK C9200E 37 mA TK C9201EG 2 5 W TK C9300U 220 mA TK C9300E 40 mA TK C9301EG Ambient temperature 10 f to 50 f 14 g to 122 g Operation 0 f to 40 f 32 g to 104 g Recommended Mass 280 g TK C9200U TK 9200E TK C9300U TK C9300E 470 g TK C9201EG TK C93...

Страница 16: ...TK C9200U TK C9200E TK C9201EG TK C9300U TK C9300E TK C9301EG COLOR VIDEO CAMERA LST0984 001A Q 2009 Victor Company of Japan Limited ...

Отзывы: