background image

Built-in PAN, TILT, and ZOOM
Controls

The RM-P2580 lets you select any of
eight JVC TK-C675B cameras it
controls in a surveillance network.
Then, using push-buttons and joy stick
you can control pan, tilt, and zoom to
scan an area or focus on a specific
action. You can also fine-tune picture
quality using Focus and Iris controls.

Auto Panning

Using the remote controller, you can
program automatic panning
movements of individual cameras. 
A camera set up for automatic 
panning constantly patrols the area
under surveillance with low-speed
horizontal camera movements between
two designated points at a constant
time interval.

Auto Sequence Mode

Press the Auto switch and the 
RM-P2580 enters the Auto Sequence
Mode. Using a built-in sequential
switcher the controller sequentially
displays the images captured by a
network of up to eight CCTV cameras.
The cameras are selected in preset
number order with images displayed for
a fixed period.

Auto Patrol Mode

The Auto Patrol Mode provides three
Preset Sequence Mode settings and
64 presettings for surveillance coverage
of a designated area by random or
sequential panning. So you can set up
high-speed camera movements
between multiple pre-set positions in
the sequence and the time intervals of

your choice. You can also use this
function for individual or multiple
cameras.

Auto Alarm Operation

Operation of the RM-P2580 can be
interlocked with peripheral alarm
equipment connected through 
Data I/O Terminals at the back of the
unit. The user can then select operation
in either Alarm Priority or Manual
Priority mode. With the Alarm Priority
mode selected, the controller interrupts
the programed operation automatically
at the shot by the camera for which the
alarm signal is received. The controller
also issues visual and audio alarms,
while indicating the camera ID number
on the Camera Display. In Manual
Priority mode only the camera ID is
displayed with all operations remaining
unaffected.

Input/Output Terminals

The RM-P2580 is equipped with a full
range of input/output terminals. These
let you hook the controller up to a bank
of eight monitors, with one monitor
allocated to each camera, as well as
alarm equipment and time-lapse VCR.
The unit’s RS-485 Connection allows
cascaded connection of cameras.

Area Title

The RM-P2580 also takes advantage
of the Area Title function of the 
TK-C675B. This innovative function
divides the space covered by a camera
into 16 units, with a 16-character ID
allocated to each unit. At the touch of a
button you can accurately position the
camera to view a designated area.

Key Lock Function

Activating Key Lock disables the joy
stick and operating push-buttons on
the control panel to prevent operating
errors.

RS-232C Interface

The RM-P2580 comes with an 
RS-232C terminal to allow control
external components.

POSITION display

AUTO PATROL button

AUTO PAN
button

PAN/TILT
control lever

POSITION display

SET button

Camera 1

Camera 2

Camera 3

Camera 6

Camera 5

Camera 4

POSITION display

Lights up.

AUTO button

CAMERA display

q

@3

we rty

u

i

o

!0

!1

!3 !2

!4

!5

!6

!7

!8

!9

@0

@1

@2

@9

@8

@7

@6

@5

@4

#4

#3

#1 #0

#2

q

[MENU] button (with an indicator)

w

[SET] button

e

[ALARM] indicator

r

[POWER] indicator

t

[KEY LOCK] indicator

y

[CAMERA] display

u

[POSITION] display

i

[AUTO] button

o

[F1, F2, F3] Function buttons

!0

[CAMERA] button

!1

[POSITION] button

!2

[PAN/TILT] control lever

!3

[OPTION 1,2]

!4

[AUTO PATROL] button

!5

[-,+] Negative and positive buttons

!6

[AUTO PAN] button

!7

[ENTER] button

!8

[1 to 0/HOME] Numeric key buttons

!9

[CLEAR] button

@0

[ZOOM WIDE, TELE] ZOOM control
buttons

@1

[FOCUS NEAR, FAR] FOCUS control
buttons

@2

[IRIS CLOSE, OPEN] Iris control buttons

@3

[SPEED] Speed button and indicators

@4

[AC~INPUT] AC power input connector

@5

[POWER] switch

@6

[TO CAMERA] Camera control signal
connectors

@7

[DATA I/O] Data signal input/output
terminals

@8

[SERIAL-1] External extension connector 1
(D-sub 9-pin male connector)

@9

[SERIAL-2] External extension connector 2
(D-sub 9-pin male connector)

#0

[MONITOR OUTPUT 2] Video signal
output connector 2

#1

[MONITOR OUTPUT 1] Video signal
output connector 1

#2

[VIDEO INPUT] Video signal input
connectors

#3

[VIDEO OUTPUT] Video signal output
connectors

#4

DIP switch

Controls, Connectors and
Indicators

Содержание RMP-2580U - Remote Controller For Color Domes

Страница 1: ...ost Effective R 䡲 Built in PAN TILT and ZOOM controls 䡲 Auto Panning 䡲 Built in 8ch Sequential Switcher Function 䡲 Auto Patrol Mode 䡲 Auto Alarm Operation 䡲 Multi Alarm Inputs Outputs 䡲 8 Video Inputs Outputs with Auto Termination 䡲 Area Title 䡲 Operation Lock Function 䡲 Interface RS 485 for Camera and RS 232C for External Unit SYSTEM mini ...

Страница 2: ...equential Switching to Auto Patrol There is even an Auto Alarm operation which you can set up to interrupt pre programmed operations and view the scene where an alarm is activated A comprehensive selection of input output terminals also lets you add additional monitors time lapse VCR and other peripherals to further customize your CCTV system Best of all the compact RM P2580 remote controller lets...

Страница 3: ... RM P2580 is equipped with a full range of input output terminals These let you hook the controller up to a bank of eight monitors with one monitor allocated to each camera as well as alarm equipment and time lapse VCR The unit s RS 485 Connection allows cascaded connection of cameras Area Title The RM P2580 also takes advantage of the Area Title function of the TK C675B This innovative function d...

Страница 4: ...utputs 16 Number of UNIT ALARM outputs 1 line open collector Number of AUTO outputs 1 line open collector Number of CAM SW circuits 1 Video lines Number of inputs 8 BNC Level Composite 1V p p Number of outputs 2 BNC Supply voltage 100 120V AC Power consumption Approx 3W Ambient temperatures Operating 14 F to 122 F 10 to 50 C Recommended 32 F to 104 F 0 to 40 C Mass Approx 3 3lbs 1 5kg Dimensions U...

Отзывы: