1-4

1. Service should be performed by qualified personnel only.
2. This equipment has been  designed  and  manufactured  to  meet  international  safety  standards.
3. It  is  the  legal  responsibility  of  the  repairer  to  ensure  that  these  safety  standards  are  maintained.
4. Repairs  must  be  made  in  accordance  with  the  relevant  safety  standards.
5. It  is  essential  that  safety  critical  components  are  replaced  by  approved  parts.
6. If  mains  voltage  selector  is  provided,  check  setting  for  local  voltage.

1. This  design  of  this  product  contains  special  hardware  and  many  circuits  and  components specially  

for  safety  purposes.    For  continued  protection,  no  changes  should  be  made  to  the  original  
design  unless  authorized  in  writing  by  the  manufacturer.    Replacement  parts  must  be  identical  to  
those  used  in  the  original  circuits.    

2. Any unauthorised design alterations or additions will void the manufacturer's guarantee ; furthermore the 

manufacturer cannot  accept responsibility for personal injury or property damage resulting therefrom.

3. Essential safety critical components are identified by (    ) on the Parts List and by shading on the 

schematics, and must never be replaced by parts other than those listed in the manual. Please note 
however that many electrical and mechanical parts in the product have special safety related 
characteristics. These characteristics are often not evident from visual inspection. Parts other than 
specified by the manufacturer may not  have  the  same  safety  characteristics  as  the  recommended  
replacement  parts  shown  in  the  Parts  List  of the Service  Manual and may  create  shock,  fire,  or  
other  hazards.

4. The  leads  in  the  products  are  routed  and  dressed  with  ties,  clamps,  tubings,  barriers  and  the  

like  to  be  separated  from  live  parts,  high  temperature  parts,  moving  parts  and/or  sharp  edges  
for  the  prevention  of  electric  shock  and  fire  hazard.    When  service  is  required,  the  original  lead  
routing  and  dress  should  be  observed,  and  it  should  be  confirmed  that  they  have  been  returned  
to  normal,  after  re-assembling.

!

Burrs formed during molding may be left over on some parts of the chassis. Therefore, 
pay attention to such burrs in the case of preforming repair of this system.

(U.K only)

Содержание RC-ST1BK

Страница 1: ...Y OF JAPAN LTD RC ST1SL RC ST1RD RC ST1BK Contents Area Suffix B U K E Contnental Europe EN Northern Europe EV Eastern Europe Specification 1 2 SafetyPrecautions 1 3 Importantoflaserproducts 1 5 preventingstaticelectricity 1 6 BlockDiagram 1 8 SchematicDiagrams 1 10 Assembly 1 14 ...

Страница 2: ...ermalloy head for recording playback magnetic head for erasure Fast wind time Approx 120 sec C 60 cassette General Speakers 10 cm 2 8 Power output 2 W per channel min RMS driven into 8 at 1 kHz with no more than 10 total harmonic distortion IEC 268 3 Output terminal PHONES 1 3 5 mm stereo Power supply AC 230 V 50 Hz DC 12 V R20 D 13F cells 8 Power consumption 19 W power on mode 2 5 W standby mode ...

Страница 3: ...antenna terminals knobs metal cabinet screw heads headphone jack control shafts etc to be sure the product is safe to operate without danger of electrical shock Do not use a line isolation transformer during this check Plug the AC line cord directly into the AC outlet Using a Leakage Current Tester measure the leakage current from each exposed metal parts of the cabinet particularly any exposed me...

Страница 4: ...ge resulting therefrom 3 Essential safety critical components are identified by on the Parts List and by shading on the schematics and must never be replaced by parts other than those listed in the manual Please note however that many electrical and mechanical parts in the product have special safety related characteristics These characteristics are often not evident from visual inspection Parts o...

Страница 5: ...ad Betrakta ej strålen VARO Avattaessa ja suojalukitus ohitettaessa olet alttiina näkymättömälle lasersäteilylle Älä katso säteeseen ADVARSEL Usynlig laserstråling ved åbning når sikkerhedsafbrydere er ude af funktion Undgå udsættelse for stråling ADVARSEL Usynlig laserstråling ved åpning når sikkerhetsbryteren er avslott unngå utsettelse for stråling Position and position of labels WARNING LABEL ...

Страница 6: ...ort and before installation both sides of the laser diode on the replacement optical pickup are shorted After replacement return the shorted parts to their original condition Refer to the text 2 Do not use a tester to check the condition of the laser diode in the optical pickup The tester s internal power source can easily destroy the laser diode Handling the traverse unit optical pickup 1 Do not ...

Страница 7: ...1 7 M E M O ...

Страница 8: ...1 8 Block Diagram ...

Страница 9: ...1 9 ...

Страница 10: ...1 10 Main Circuit Schematic Diagrams ...

Страница 11: ...1 11 ...

Страница 12: ...1 12 CD Servo Circuit ...

Страница 13: ...1 13 ...

Страница 14: ...1 14 Assembly 1 S1 18 19 S1 S1 10 11 7 5 4 6 3 2 1 ...

Страница 15: ...1 15 S1 11 12 13 14 15 S4 S3 21 20 S1 18 19 S2 16 17 S4 S1 S1 9 8 ...

Страница 16: ...1 16 Assembly 2 17 6 7 S10 5 4 3 2 1 8 7 9 S9 11 12 13 S8 10 14 18 19 S6 20 S7 22 21 16 15 S3 S2 S1 23 S4 S5 ...

Страница 17: ...1 17 M E M O ...

Страница 18: ...1 18 Assembly 3 S7 S7 S6 S8 S8 11 S5 9 8 S 7 FRONT CABINET CD TRAY ...

Страница 19: ...1 19 8 S4 10 7 6 S3 S3 S3 S3 S2 5 4 1 3 2 S1 ...

Страница 20: ... No MB062 2003 11 JVC Euorpe Limited JVC House JVC Budiness Park 12 Priestley Way London NW2 7BA United Kingdom ...

Отзывы: