MX-S6MD
1-35
LCD ALL INDICATION, TIME COMPRESSION TEST MODE
POWER ON
Press [POWER key],[1 key] and
[STOP key] together of the
Remote controller (1st time)
Press [POWER key],[1 key] and
[STOP key] together of the
Remote controller (2nd time)
Press [POWER key],[1 key] and
[STOP key] together of the
Remote controller (3rd time)
Press [POWER key],[1 key] and
[STOP key] together of the
Remote controller (4th time)
LCD and LED are all ON
Full color LED is WHITE
Inspection for static
electricity broken check mode
for full color LED (RED)
1.Setting the TEST MODE
2.Fast forward of CLOCK/SLEEP TIMER
(press any key) Change to normal indication
It can check for red color chip part
Inspection for static
electricity broken check mode
for full color LED (GREEN)
It can check for green color chip part
Inspection for static
electricity broken check mode
for full color LED (BLUE)
It can check for blue color chip part
Caution:Full color LED is keep white condition, when loop out by any key at test mode.
Including the ALL LED ON mode and Static electricity broken thes, clock count up is change to
1min. to 1sec.
Check for only [CLOCK mode] and [SLEEP TIMER].
3.Release the TEST MODE
TEST MODE is release by disconnect the AC power cord.