(No.YA301)1-27
< Page 2 of screen >
5.1.7 METHOD OF DISPLAY WHEN A RASTER IS NOT OUTPUT
In the state where a raster is not output by breakdown of the set, an error is displayed by blink of the POWER LED.
< Explanation of operation >
If error is detected, the power is turned off.
Shortly after a power is turned off, POWER LED will be blinked.
Power cannot be turned on until the power cord takes out and inserts, after a power is turned off.
Detection item
Display
Detection content
Diagnosis
signal (line)
Detection timing
Fan lock
FAN
Not used.
---
---
Abnormal of operation of
PANEL
ALM
Not used.
---
---
Abnormal rise
oftemperature in PANEL
TMP
Not used.
---
---
Abnormal rise of
temperature in AUDIO
PWB
ATP
Not used.
---
---
Short circuit detection of
AUDIO PWB
ASH
Not used.
---
---
Panel communication
PNL
Not used.
---
---
Sub memory
MEM Not used.
---
---
Temp. sensor
TMP
Not used.
---
---
Audio control
AIO
Not used.
---
---
Abnormal rise of CARD
VIEWER PWB
CARD
Comfirmation of reply of ACK signal which uses
SDA communication.
IC1001
[CARD VIEWER PWB]
SDA
If it checks whenever SDA
communication is performed and
no reply of ACK signal an error
will be counted.
Type of error
Display
POWER LED flash cycle
Low bias line short protection
LOB
Low luminance blue turnig on and off at 1 second intervals.
ATSC digital tuner communication error
---
Low luminance blue Flash 2.0 second / Low luminance blue Out 2.0 seconds
Fan lock
---
Low luminance blue Flash 2.0 second / Low luminance blue Out 2.0 seconds