1-18 (No.YA204)
4.6
INITIAL SETTING VALUES IN THE SERVICE MODE
• Perform fine-tuning based on the "initial values" using the remote control when in the Service mode.
• The "initial values" serve only as an indication rough standard and therefore the values with which optimal display can be achieved
may be different from the default values. But, don't change the values that are not written in "ADJUSTMENT PROCEDURE". They
are fixed values.
4.6.1 VIDEO SYSTEM SETTING
4.6.2 AUDIO SYSTEM SETTING (*Fixed values)
4.6.3 PANEL CONTOROL SYSTEM SETTING (*Fixed values)
4.6.4 DRIVE SYSTEM SETTING (*Fixed values)
Item
No.
Item name
Variable
range
Setting value
PAL
SECAM NTSC
S001 PREPARE
0 to 31
0
0
0
S002 NTSC BL
0 to 15
0
0
0
S003 NTSC CNT
0 to 255
36
36
36
S004 NT CR OF
0 to 15
6
6
6
S005 NT CB OF
0 to 15
6
6
6
S006 525i BL
0 to 15
0
0
0
S007 525i CNT
0 to 255
36
36
36
S008 5i CB OF
0 to 15
0
0
0
S009 5i CR OF
0 to 15
0
0
0
S010 5i CR GN
0 to 15
6
6
6
S011 5i CB GN
0 to 15
6
6
6
S012 HD BL
0 to 63
57
57
57
S013 HD CB OF
0 to 63
58
58
58
S014 HD CR OF
0 to 63
60
60
60
S015 RT CONT
0 to 15
7
7
7
S016 RT CB OF
0 to 15
4
4
4
S017 RT CR OF
0 to 15
8
8
8
S018 RT CL GA
0 to 15
12
12
12
S019 PC CL MB
0 to 7
0
0
0
S020 PC CL LB
0 to 31
0
0
0
S021 PC CL MR
0 to 71
0
0
0
S022 PC CL LR
0 to 31
0
0
0
S023 (Not display)
0 to 255
0
0
0
S024 (Not display)
0 to 255
0
0
0
S025 (Not display)
0 to 255
0
0
0
S026 (Not display)
0 to 255
0
0
0
S027 (Not display)
0 to 255
0
0
0
S028 (Not display)
0 to 255
0
0
0
S029 (Not display)
0 to 255
0
0
0
S030 R DRIVE
0 to 255
147
147
147
S031 G DRIVE
0 to 255
133
133
133
S032 B DRIVE
0 to 255
110
110
110
S033 (Not display)
0 to 255
0
0
0
S034 (Not display)
0 to 255
0
0
0
S035 (Not display)
0 to 255
0
0
0
S036 (Not display)
0 to 255
0
0
0
S037 (Not display)
0 to 255
0
0
0
S038 (Not display)
0 to 255
0
0
0
S039 ILA COM
0 to 1
0
0
0
Item
No.
Item name
Variable
range
Setting value
PAL
SECAM NTSC
T001 IN LEVEL
0 to 255
0
0
0
T002 LOW SEP
0 to 255
0
0
0
T003 HIGH SEP
0 to 255
0
0
0
T004 AFC
0 to 255
4
4
4
T005 (Not display)
0 to 255
0
0
0
T006 ATT V ON
0 to 1
0
0
0
T007 ATT U ON
0 to 1
0
0
0
T008 ATT C ON
0 to 1
0
0
0
T009 (Not display)
0 to 255
0
0
0
T010 (Not display)
0 to 255
0
0
0
Item
No.
Item name
Variable
range
Setting value
PAL
SECAM NTSC
P001 TM HOR H
00 to FF
00
00
00
P002 TM HOR L
00 to FF
00
00
00
P003 TM MIN
00 to FF
00
00
00
P004 TEMP0
0 to 255
0
0
0
P005 (Not display)
0 to 255
0
0
0
P006 (Not display)
0 to 255
0
0
0
P007 (Not display)
0 to 255
0
0
0
P008 (Not display)
0 to 255
0
0
0
P009 (Not display)
0 to 255
0
0
0
P010 (Not display)
0 to 255
0
0
0
Item
No.
Item name
Variable
range
Setting value
PAL
SECAM NTSC
D001 SLV GN
00 to 3F
18
18
18
D002 SLVH GN
00 to 3F
13
13
13
D003 SLH GN
00 to 3F
1A
1A
1A
D004 SLV Pf
00 to 03
01
01
01
D005 SLH Pf H
00 to 01
00
00
00
D006 SLH Pf L
00 to 03
02
02
02
D007 SL EGCON
00 to 3F
00
00
00
D008 SL EGONF
00 to 01
01
01
01
D009 SL CRGON
00 to 3F
04
04
04
D010 SL CRGON
00 to 01
01
01
01
D011 SL ON OF
00 to 01
01
01
01
D012 SV GN
00 to 3F
29
29
29
D013 SVH GN
00 to 3F
1F
1F
1F
D014 SH GN
00 to 3F
2E
2E
2E
D015 SV Pf
00 to 03
01
01
01
D016 SV PfH
00 to 01
01
01
01