![JVC KY-F70 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/jvc/ky-f70/ky-f70_instructions-manual_177143060.webp)
E60
@ @ @ @ @ @
Function/variable range
Used to adjust the video level when using auto iris, ALC
and EEI.
Raise the level: increase the number
Lower the level: decrease the number
[Variable range: –128 ~ 127]
Used to set the iris level when the IRIS MODE is set to
MANUAL.
Open iris: increase the number
Close iris: decrease the number
[Variable range: 0 ~ 255]
Used to set the shutter mode.
STEP:
the shutter speed can be changed using the
SPEED submenu item.
V.SCAN: used to clear the horizontal line noise when re-
cording a PC monitor by adjusting to the scan
speed of the monitor.
The shutter can be changed in detail using the
LEVEL submenu item. (Recording a PC moni-
tor (
Z
page 42))
EEI:
Used to automatically change the shutter speed
depending on the object brightness.
(max: 1/255.1)
OFF:
• 1/30 when VGA is set to the DRAFT mode
• 1/7.5 when VGA is set to the FINE mode
• 1/7.5 when in the SXGA mode
The shutter sped can be changed when the shutter is set
to STEP or V.SCAN.
[STEP variable range:
1/1, 1/2, 1/4, 1/8, 1/15, 1/30,
1/60, 1/125, 1/250, 1/500,
1/1000, 1/2000]
[V.SCAN variable range: 1/30, ~ 1/5906. 8]
Default value
0
128
STEP
STEP : 1/8
V. SCAN :
1/30
Menu item
AE LEVEL
IRIS LEVEL
SHUTTER
SPEED
6. Menu screen settings (continued)
REC mode quick menu screen