1-12 (No.MA148)
3.2.2 Removing the connector board
(See Figs.3 to 5)
CAUTION:
Before disconnecting the flexible wire from the pickup, solder
the short-circuit point on the pickup. No observance of this in-
struction may cause damage of the pickup.
(1) Remove the screw
B
fixing the connector board.
(2) Solder the short-circuit point on the connector board.
(3) Disconnect the flexible wire from the pickup.
(4) Move the connector board in the direction of the arrow to
release the two joints
b
.
(5) Unsolder the wire on the connector board if necessary.
CAUTION:
Unsolder the short-circuit point after reassembling.
Fig.3
Fig.4
Fig.5
B
Connector board
Pickup
Short-circuit point
Joints b
Wires
Pickup
Short-circuit point
(Soldering)
Flexible wire
B
Flexible wire
Connector board
Frame
Содержание KD-G611
Страница 31: ... No MA148 1 31 ...