1-40 (No.YA011)
H. POSITION
Signal
generator
Remote
control unit
[4. DEF]
4. H-CENT
(1) Receive the circle pattern signal.
(2) Select 4. DEF.
(3) Set the initial setting value of < 4. H-CENT >.
(4) Adjust < 4. H-CENT > to become C=D as shown in
left figure.
(5) Press the [MENU] key to memorize the adjustment
value.
H. SIZE
Signal
generator
Remote
control unit
[4. DEF]
5. H-SIZE
(1) Receive the circle pattern signal.
(2) Select 4. DEF.
(3) Set the initial setting value of < 5. H-SIZE >.
(4) Adjust < 5. H-SIZE > to become the horizontal
screen size is in the table given left.
(5) Press the [MENU] key to memorize the adjustment
value.
SIDE PIN
Signal
generator
Remote
control unit
[4. DEF]
7. EW-PIN
(1) Receive the circle pattern signal.
(2) Select 4. DEF.
(3) Set the initial setting value of < 7. EW-PIN >.
(4) Adjust < 7. EW-PIN > so that second vertical lines at
the right and left edges of the screen become
straight. Also make third vertical lines become
straight.
(5) Press the [MENU] key to memorize the adjustment
value.
Item
Measuring
instrument
Test point
Adjustment part
Description
L
C
D
90%
90%
900i
Setting item
1125i
1350i
602p
5. H-SIZE
92%
92%
92%
92%
Straight