(No.YA243)1-17
4.7
INITIAL SETTING VALUE OF SERVICE MODE
(1) Adjustment of the SERVICE MODE is made on the basis of the initial setting values ; however, the new setting values which set
the screen in its optimum condition may differ from the initial setting.
(2) Do not change the initial setting values of the setting items NOT LISTED IN ADJUSTMENT PROCEDURE.
(3) --- : This mark described in each table shows "Cannot adjust it."
4.7.1 [1.V/C(S)]
No.
Setting
item
Variable
range
Initial setting value
AV-27F476/R
AV-27F476/S
RF
EXTERNAL
(S / COMPOSITE)
EXTERNAL
(COMPONENT)
STANDARD
THEATER
STANDARD
STANDARD
4 : 3
16 : 9
4 : 3
4 : 3
4 : 3
S01
BRIGHT
0 - 127
64
---
---
---
---
S02
PICTURE
0 - 127
55
---
---
---
---
S03
COLOR
0 - 127
48
---
---
---
48
S04
TINT
0 - 127
50
---
---
---
72
S05
DETAIL
0 - 63
35
---
---
40
40
S06
-
-32 - +32
---
±0
+1
+4
-4
S07
PICT+-
-32 - +32
---
-8
-7
+3
+3
S08
COLOR+-
-32 - +32
---
±0
-3
-3
---
S09
TINT+-
-32 - +32
---
±0
-3
+14
---
S10
-
-32 - +32
---
---
±0
---
---
No.
Setting
item
Variable
range
Initial setting value
AV-32F476/Y
RF
EXTERNAL
(S / COMPOSITE)
EXTERNAL
(COMPONENT)
STANDARD
THEATER
STANDARD
STANDARD
4 : 3
16 : 9
4 : 3
4 : 3
4 : 3
S01
BRIGHT
0 - 127
64
---
---
---
---
S02
PICTURE
0 - 127
55
---
---
---
---
S03
COLOR
0 - 127
45
---
---
---
43
S04
TINT
0 - 127
58
---
---
---
70
S05
DETAIL
0 - 63
35
---
---
40
40
S06
-
-32 - +32
---
±0
+3
-2
-2
S07
PICT+-
-32 - +32
---
-8
-7
+2
+2
S08
COLOR+-
-32 - +32
---
±0
-3
±0
---
S09
TINT+-
-32 - +32
---
±0
-3
+6
---
S10
-
-32 - +32
---
---
±0
---
---