AV-27F802
24
No. 51757
ADJUSTMENTS
Item
Measuring
instrument
Test point
Adjustment part
Description
Check of
B1 POWER
SUPPLY
DC Voltmeter
R507 C504
side (B1)
Q511
heatsink (
)
1. Receive a black-and-white signal.
2. Connect the DC Voltmeter to R507 C504 side (B1) and Q511 heatsink
(
).
3. Confirm that the voltage is DC134V .
+2V
-2V
RF AGC
adjustment
1. Receive a broadcast.
2. Select the No.19 RF AGC of the PICTURE MODE.
3. Press the MUTE key of the remote control unit and turn off color.
4. With the LEFT key of the remote control unit, get noise in the screen
picture. (0 side of setting value)
5. Press the RIGHT key of the remote control unit and stop when noise
disappears from the screen.
6. Change to other channels and make sure that there Is no irregular-
ity.
7. Press the MUTE key and get color out.
No.59 RF AGC
Item
Measuring
instrument
Test point
Adjustment part
Description
ADJUSTMENT OF RF AGC
FOCUS
adjustment
Signal
generator
1. Receive a crosshatch signal.
2. While looking at the screen center, adjust the FOCUS VR so that
the horizontal lines will be clear and in fine detail.
3. Adjust the H VR so that the vertical lines will be clear and in fine
detail.
4. Make sure that the picture is in focus even when the screen gets
darkened.
Note:
The final adjustment of convergence must be done after the FOCUS
adjustment. (Convergence is changed by FOCUS adjustment.)
FOCUS VR
[In HVT]
H VR
[In HVT]
Item
Measuring
instrument
Test point
Adjustment part
Description
ADJUSTMENT OF FOCUS
B1 POWER SUPPLY