GENERAL

Power requirement

Rating

: AC 110 V – 240 V

d

, 50 Hz/60 Hz

Operating

: AC 90 V – 260 V

d

, 50 Hz/60 Hz

Power consumption

: 16 W

Temperature

Operating

: 5°C to 40°C

Storage

: –20°C to 60°C

Operating position

: Horizontal only

Dimensions (W x H x D) : 400 mm x 94 mm x 270 mm
Weight

: 3.1 kg

Format

: VHS standard

Maximum recording time

(SP)

: 240 min. with E-240 video cassette 

(PAL/MESECAM)

: 160 min. with T-160 video cassette 

(NTSC)

(LP)

: 480 min. with E-240 video cassette 

(PAL/MESECAM)

(EP)

: 480 min. with T-160 video cassette 

(NTSC)

VIDEO/AUDIO

Signal system

: PAL-type colour signal and CCIR 

monochrome signal, 625 lines 
50 fields

: NTSC colour and EIA monochrome 

signals, 525 lines/60 fields

Recording system

: DA-4 (Double Azimuth) head helical 

scan system

Signal-to-noise ratio

: 45 dB

Horizontal resolution

: 250 lines (PAL/MESECAM)
: 220 lines (NTSC)

Frequency range

Normal audio

: 70 Hz to 10,000 Hz

Hi-Fi audio

: 20 Hz to 20,000 Hz

Input/Output

: RCA connectors (IN x 2, OUT x 1)

TUNER/TIMER

TV channel storage 
capacity

: 99 positions (+AUX position)

Tuning system

: Frequency synthesized tuner

Channel coverage

VHF

: (Low) 42 MHz – 175 MHz

(High) 175 MHz – 470 MHz

UHF

: 470 MHz – 870 MHz

Aerial output

: UHF channels (Adjustable E28 – E60)

Memory backup time

: Approx. 6 months

Estimated figure based on supplied 
fresh battery; actual performance may 
differ.

ACCESSORIES

Provided accessories

: RF cable,

Lithium battery CR2025,
Infrared remote control unit,
“R6/UM-3” battery x 2,

HR-J797AM.fm  Page 16  Tuesday, April 16, 2002  12:22 PM

Содержание HR-J791AM

Страница 1: ...ted on a surface that is unstable or subject to vibration 2 DO NOT block the recorder s ventilation openings or holes If the ventilation openings or holes are blocked by a newspaper or cloth etc the heat may not be able to get out CAUTION 䡲 When you are not using the recorder for a long period of time it is recommended that you disconnect the power cord from the mains outlet 䡲 Dangerous voltage in...

Страница 2: ... remote control toward the sensor window on the target component The maximum operating distance of the remote control is about 8 m NOTES When inserting the batteries be sure to insert in the correct directions as indicated under the battery cover If the remote control does not work properly remove its batteries wait for a few seconds replace the batteries and then try again Video heads cleaning Th...

Страница 3: ... supplied RF cable between the RF OUT terminal on the rear of the recorder and the TV s aerial input terminal AV Connection improves picture quality during tape playback If your TV is equipped with AV input connectors A Connect the aerial recorder and TV as shown in the illustration B Connect an AV cable between the AUDIO VIDEO OUT connectors on the rear of the recorder and the AV input connectors...

Страница 4: ...connected to an AC outlet and turn off the recorder power B Open the battery cover while pressing the release tab as illustrated C Insert a lithium battery with the plus side up and push it in To remove the lithium battery press the latch downward using a pointed non metallic object then pull out the lithium battery D Close the battery cover until it clicks in place Auto Set Up The Auto Set Up fun...

Страница 5: ...the appropriate colour system with PAL MESECAM and NTSC in Function settings If the cassette s record safety tab has been removed playback begins automatically B Start playback Press PLAY 4 MENU EXIT MAIN MENU FUNCTION SET TUNER SET INITIAL SET MENU EXIT INITIAL SET CLOCK SET LANGUAGE G CODE SHOWVIEW SETUP MENU EXIT INITIAL SET CLOCK SET LANGUAGE G CODE SHOWVIEW SETUP MENU EXIT CLOCK SET TIME DATE...

Страница 6: ...ator on the display panel starts blinking slowly To stop playback press STOP 8 on the remote control or STOP EJECT 0 on the recorder NOTE Pressing PLAY 4 REW 3 FF 5 or PAUSE 9 also cancels repeat playback Locating beginning of recordings Index Search Index codes are placed on the tape at the beginning of each recording when recording on this recorder A While the tape is not running press w or e 2o...

Страница 7: ...th a Sound Multiplex decoder A2 and a Digital stereo sound decoder NICAM as well making reception of stereo and bilingual broadcasts possible When the channel is changed the type of broadcast being received will be displayed on the TV screen for a few seconds To listen to a stereo programme press AUDIO until HIFI L R appears on the screen To listen to a bilingual programme press AUDIO until HIFI L...

Страница 8: ... Guide Program number s broadcasts are received then press OK or e If the satellite broadcast is received on your recorder s auxiliary channel L 1 or F 1 select L 1 or F 1 for the channel position to which the satellite receiver is connected Repeat steps 3 and 4 as necessary E Return to normal screen Press MENU on the remote control G CODE SHOWVIEW Timer Programing The G CODE numbers are the numbe...

Страница 9: ...een you do not want is shown To change a program press the appropriate button START STOP DATE PR DAILY WEEKLY and or SP LP EP p when the Program screen on which you want to make changes is shown E Return to normal screen Press repeatedly until no Program screen is shown F Reengage timer recording standby mode Press The recorder turns off automatically and is displayed on the display panel When AUT...

Страница 10: ...ayback SOFT Reduces image coarseness when viewing overplayed tapes containing much noise SHARP Clearer sharper edged picture when viewing images with much flat same coloured surfaces such as cartoons NOTE Select EDIT when you are editing tapes After you finish editing the tapes select AUTO 䡵 PAL MESECAM AUTO PAL MESECAM Select the appropriate colour system for recording or playback AUTO Usually se...

Страница 11: ...rol a JVC TV NOTES Some unit s brands have more than one code If the unit does not function with a specified code try other codes Depending on the type of unit some or all functions cannot be operated using this remote control It s not possible to operate a unit not equipped with a remote sensor It s not possible to set the remote control for two units at the same time Once you have set the remote...

Страница 12: ...ion and its operations A Make connections Example When using this recorder as the source player When using this recorder as the recording deck connect this recorder s AV input connectors to the AV output connectors on the other recorder If the source player is monaural connect the audio output connector on the source player to the left audio input connector on this recorder B Load cassettes Insert...

Страница 13: ... control During search still or frame by frame playback the picture will be distorted and there may be a loss of colour ATTENTION When this recorder is connected to a multi system TV the audio signal may not be heard or may be noisy if the colour system select switch of the TV is adjusted to the AUTO position In such a case set the TV s colour system select switch to the appropriate position which...

Страница 14: ...etting for those channels may be incorrect Select the appropriate TV system for those channels Refer to TV System Selection When you see the picture but the audio can t be heard or sounds unnatural Since your recorder memorises all detected stations even if the reception condition is poor some of those stored stations may produce a noisy picture To delete those stations refer to Delete A Channel M...

Страница 15: ... pointer next to CH EDIT then press OK or e C Select channel to fine tune Press rt until the channel you want to tune begins blinking then press OK twice The FRQ number for that channel starts blinking D Perform tuning Press rt until the picture becomes clearer then press OK or e Repeat steps C and D as necessary E Return to normal screen Press MENU TV System Selection When you see the picture but...

Страница 16: ... PAL type colour signal and CCIR monochrome signal 625 lines 50 fields NTSC colour and EIA monochrome signals 525 lines 60 fields Recording system DA 4 Double Azimuth head helical scan system Signal to noise ratio 45 dB Horizontal resolution 250 lines PAL MESECAM 220 lines NTSC Frequency range Normal audio 70 Hz to 10 000 Hz Hi Fi audio 20 Hz to 20 000 Hz Input Output RCA connectors IN x 2 OUT x 1...

Отзывы: