![JVC HR-J282EU Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/jvc/hr-j282eu/hr-j282eu_service-manual_182116055.webp)
MAINTENANCE/INSPECTION PROCEDURE
4-20
The recording density of a VCR(VCP) is much higher than
that of an audio tape recorder. VCR(VCP) components must
be very precise, at tolerances of 1/1000mm, to ensure com-
patiblity with other VCRs. If any of these components are
worn or dirty, the symptoms will be the same as if the part is
defective. To ensure a good picture, periodic inspection and
maintenance, including replacement of worn out parts and
lubrication, is necessary.
Schedules for maintenance and inspection are not fixed
because they vary greatly according to the way in which the
customer uses the VCR(VCP), and the environment in which
the VCR(VCP) is used.
But, in general home use, a good picture will be maintained
if inspection and maintenance is made every 1,000 hours.
The table below shows the relation between time used and
inspection period.
Table 1
(1) Grease : Kanto G-311G (Blue) or equivalent
(2) Isopropyl Alcohol or equivalent
(3) Cleaning Patches
(4) Grease : Kanto G-381(Yellow)
(1) Cleaning video head
First use a cleaning tape. If the dirt on the head is too
stubborn to remove by tape, use the cleaning patch. Coat
the cleaning patch with Isopropyl Alcohol. Touch the
cleaning patch to the head tip and gently turn the
head(rotating cylinder) right and left.
(Do not move the cleaning patch vertically. Make sure
that only the buckskin on the cleaning patch comes into
contact with the head. Otherwise, the head may be dam-
aged.)
Thoroughly dry the head. Then run the test tape. If lso-
propyl Alcohol remains on the video head, the tape may
be damaged when it comes into contact with the head
surface.
(2) Clean the tape transport system and drive system, etc,
by wiping with a cleaning patch wetted with Isporopyl
Alcohol.
1
It is the tape transport system which comes into contact
with the running tape. The drive system consists of those
parts which moves the tape.
2
Make sure that during cleaning you do not touch the tape
transport system with the tip of a screw driver and no that
force is that would cause deforming or damage applied to
the system.
2. Required Maintenance
3. Scheduled Maintenance
5) Maintenance Procedure
5-1) Cleaning
NOTES:
About 1
year
One hour
Two hours
Three hours
When
inspection is
necessary
Average
hours used
per day
About 18
months
About 3
years
4. Supplies Required for Inspection and
Maintence
Fig. C-9-4
Drum
(Rotating Cylinder)
Head Tip
Coat With Isopropyl Alcohol
Touch this section of cleaning
patch to the head tip and gently
turn the Drum (Rotating Cylinder)
Cleaning Patch
Содержание HR-J282EU
Страница 2: ......
Страница 34: ......
Страница 57: ...4 22 GEAR F R GEAR AY P2 P3 ...
Страница 66: ...MEMO ...
Страница 67: ......
Страница 68: ...VICTOR COMPANY OF JAPAN LIMITED VIDEO DIVISION Printed in Japan S40894 ...
Страница 82: ...3 45 3 46 LOCATION GUIDE PRINTED CIRCUIT BOARD DIAGRAMS 1 MAIN P C Board Solder Side ...