background image

Dear Customer,

This apparatus is in conformance with the valid 
European directives and standards regarding 
electromagnetic compatibility and electrical safety. 

European representative of Victor Company of Japan, 
Limited is:
JVC Technical Services Europe GmbH
Postfach 10 05 04
61145 Friedberg
Germany

Information for Users on Disposal of Old 
Equipment

[European Union]

This symbol indicates that the 
electrical and electronic equipment 
should not be disposed as general 
household waste at its end-of-
life. Instead, the product should 
be handed over to the applicable 
collection point for the recycling of 
electrical and electronic equipment 
for proper treatment, recovery and 
recycling in accordance with your 
national legislation.

By disposing of this product 
correctly, you will help to conserve 
natural resources and will help 
prevent potential negative effects 
on the environment and human 
health which could otherwise 

be caused by inappropriate waste handling of this 
product. For more information about collection point 
and recycling of this product, please contact your 
local municipal office, your household waste disposal 
service or the shop where you purchased the product.

Penalties may be applicable for incorrect disposal of 
this waste, in accordance with national legislation.

(Business users)

If you wish to dispose of this product, please visit our 
web page http://www.jvc.eu/ to obtain information 
about the take-back of the product.

[Other Countries outside the European Union]

If you wish to dispose of this product, please do so in 
accordance with applicable national legislation or other 
rules in your country for the treatment of old electrical 
and electronic equipment.

Attention:

This symbol is 
only valid in the 
European Union.

WARNING:

  TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS 

APPARATUS TO RAIN OR MOISTURE.

WARNING:

  THIS APPARATUS MUST BE CONNECTED TO A MAINS SOCKET OUTLET 

WITH A PROTECTIVE EARTHING CONNECTION.

CAUTION:

  DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED. 

REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE.

IMPORTANT SAFETY INSTRUCTIONS

1)  Read these instructions.
2)  Keep these instructions.
3)  Heed all warnings.
4)  Follow all instructions.
5)  Do not use this apparatus near water.
6)  Clean only with dry cloth.
7)  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8)  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including 

amplifiers) that produce heat.

9)  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades 

with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide 
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult 
an electrician for replacement of the obsolete outlet.

10) Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and 

the point where they exit from the apparatus.

11) Only use attachments/accessories specified by the manufacturer.
12) Use only with the cart, stand, tripod, bracket, or table specified by the 

manufacturer, or sold with the apparatus. When a cart is used, use caution when 
moving the cart/apparatus combination to avoid injury from tip-over.

13) Unplug this apparatus during lightning storms or when unused for long periods of 

time.

14) Refer all servicing to qualified service personnel. Servicing is required when the 

apparatus has been damaged in any way, such as power-supply cord or plug is 
damaged, liquid has been spilled or objects have fallen into the apparatus, the 
apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

15) Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall 

be placed on the apparatus.

16) Batteries shall not be exposed to excessive heat such as sunshine, fire or the like.
17) When discarding batteries, environmental problems must be considered and the local rules or laws governing 

the disposal of these batteries must be followed strictly.

3

ENGLISH

European Union only

FCC NOTICE
CAUTION:

 Changes or modifications not approved by JVC could void the user’s authority to operate the 

equipment.

NOTE: 

This equipment has been tested and found to comply with the limits for a Class A digital device, 

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a commercial environment. This equipment generates, 
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction 
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential 
area is likely to cause harmful interference in which case the user will be required to correct the interference at 
his own expense.

IMPORTANT RECYCLING INFORMATION

This product has a fluorescent lamp that contains mercury. Disposal of these materials 
may be regulated in your community due to environmental considerations. For disposal 
or recycling information, please contact your local authorities or for USA, the Electronic 
Industries Alliance: http://www.eiae.org

U.S.A. only

EMC Supplement

This equipment is in conformity with the provisions 
and protection requirements of the corresponding 
European Directives. This equipment is designed for 
professional video appliances and can be used in the 
following environments:
•  Controlled EMC environment (for example purpose 

built broadcasting or recording studio), and rural 
outdoors environment (far away from railways, 
transmitters, overhead power lines, etc.)

In order to keep the best performance and ensure 
electromagnetic compatibility, we recommend to use 
cables not exceeding the following length:

Cable  

Length

Power cord  

2.0 m

(attached cable (H05VV-F 3 x 0.75 mm

2

))

Video signal cable (coaxial cable) 

2.0 m

Audio signal cable (shielded cable) 

1.5 m

DVI cable (shielded cable) 

2.0 m

RS-232C cable (shielded cable) 

2.0 m

(A straight cable with a D-sub 9-pin connector)

RS-485 cable (twist pair cable) 

2.0 m

(A straight LAN cable)

REMOTE cable (twist pair cable) 

2.0 m

(A straight LAN cable)

The inrush current of this apparatus is 14.80 ampere.

CAUTION

In case where the strong electromagnetic waves or 
magnetism are near the audio cable or the signal 
cable, the sound or the picture will contain noise. In 
such cases, please keep the cable away from the 
sources of the disturbance.

DT-V17G1_EN.indd   3

DT-V17G1_EN.indd   3

09.12.3   7:55:11 PM

09.12.3   7:55:11 PM

Содержание DT-V17G1

Страница 1: ...ce the risk of electric shock Do not remove cover or back No user serviceable parts inside Refer servicing to qualified service personnel RISK OF ELECTRICAL SHOCK DO NOT OPEN The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to con...

Страница 2: ...product through openings as they may touch dangerous voltage points or short circuit the parts which could result in a fire or electric shock Never spill liquid of any kind on the product Never place anything on the product Placing liquids naked flames cloths paper etc on the product may cause a fire Do not apply any strong shock to the LCD panel Do not hit any object against it or push it with a ...

Страница 3: ...us When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects ...

Страница 4: ...or may fall over Place the monitor on a mat to avoid scratching the table surface Do not lift up the stand when the stand plate is attached to the lower position of the stand body When the battery is attached the stand may not be lifted up depending on the type of the battery To detach the stand CAUTION Lay the monitor on a cloth with the LCD panel facing down to prevent the LCD panel from being d...

Страница 5: ...l the monitor on a shelf etc by changing the position of the bottom plate of the stand to a rearward position CAUTION Lay the monitor on a cloth with the LCD panel facing down to prevent the LCD panel from being damaged When you change the position of the bottom plate of the stand be sure to install the monitor using screws not provided 1 Remove the bottom plate of the stand from the stand body 2 ...

Страница 6: ...ect the color of the tally lamp from GREEN or RED TALLY SELECT in FUNCTION SETTING on page 16 and External Control on page 20 NO EFFECT is displayed when you press a button which is not available for the current input or signal format the lamp lights even when the function does not actually work The items controlled by the MAKE system cannot be controlled by the buttons on the front panel REMOTE O...

Страница 7: ...layed when an error occurs 5 Time code When the input signal includes no time code TC is displayed r on page 6 Select audio channels emitted from the speakers L R and the AUDIO MONITOR OUT OUT1 L OUT2 R terminals when EMBEDDED AUDIO signals come in to the E AUDIO HD SD SDI terminal IN1 or IN2 and SDI input 1 or 2 is selected You have to choose a group of selectable audio channels before the channe...

Страница 8: ... terminal 6 E AUDIO HD SD SDI IN 1 IN 2 terminals BNC Input terminals for the HD SD SDI signals The terminals accept also EMBEDDED AUDIO signals including up to 12 audio channels with a sampling frequency of 48 kHz Use both terminals when selecting DUAL LINK SDI for the input 7 E AUDIO HD SD SDI SWITCHED OUT terminal BNC Output terminal for the HD SD SDI signals The SDI signals of the current inpu...

Страница 9: ... battery for DC 12 V power supply by using 2 screw holes Choose the appropriate screw holes from 1 2 or 3 according to the type of external battery Use the Anton Bauer Dionic 90 mount QR DXC M3A external battery CAUTION Do not use the external battery for DC 24 V power supply Use only the battery specified above If a heavy battery is used it may fall off depending on the way the monitor is used Wh...

Страница 10: ...p 1080 30p 30 1080 29 97p 1080 29 97p 31 1080 25p 1080 25p 32 1080 24p 1080 24p 33 1080 23 98p 1080 23 98p 34 1080 30psF 1080 30psf 3 3 35 1080 29 97psF 1080 29 97psf 4 4 36 1080 24psF 1080 24psf 37 1080 23 98psF 1080 23 98psf 38 1080 25psF 1080 25psf 1 Analog component signals are compatible with Y on sync signals 2 Compatible with EMBEDDED AUDIO signals 3 The signal is recognized as 1080 60i and...

Страница 11: ...ignals the resolution is shown Specification of the DVI D HDCP terminal Connect it to the DVI D output terminal on a personal computer Pin No Input signal Pin No Input signal Pin No Input signal 1 T M D S Data 2 9 T M D S Data 1 17 T M D S Data 0 2 T M D S Data 2 10 T M D S Data 1 18 T M D S Data 0 3 T M D S Data 2 shield 11 T M D S Data 1 shield 19 T M D S Data 0 shield 4 NC 12 NC 20 NC 5 NC 13 N...

Страница 12: ...s in PICTURE FUNCTION 1 Memorized for each input BACK LIGHT Adjusts the brightness of the display 3G SDI LEVEL B Selects the data stream from two HD SDI signals multiplexed when a 3G SDI level B signal comes in SDI DUAL LINK Activates deactivates the DUAL LINK function of SDI signals DUAL LINK is displayed when the setting is set to ON No other status indications of SDI signals are displayed Set t...

Страница 13: ... the area marker 4 3 14 9 13 9 2 35 1 1 85 1 1 66 1 SAFETY MARKER Activate deactivate the safety marker and select the style of it NOTE SAFETY AREA Adjust the area of the safety marker 80 100 FRAME Displays hides the frame indicating the area of the specified aspect ratio OFF ON CENTER MARKER Displays hides the marker indicating the center position of the picture OFF ON LINE BRIGHTNESS Adjust the ...

Страница 14: ...lay 10dB 8dB 6dB 4dB 2dB BAR BRIGHTNESS Select the brightness of the level meter LOW HIGH PEAK HOLD Activates deactivates the peak hold function of the level meter OFF ON 1 Memorized for each input Settings of E AUDIO GROUP The setting values and selectable audio channels of EMBEDDED AUDIO signals are as follows G means GROUP 1G channel s 1 2 3 4 1 2 3 4 1 4 1G 2G channel s 5 6 7 8 5 6 7 8 5 8 2G ...

Страница 15: ...ronization with signals Item To do Setting value NO SYNC ACTION Select the screen status when no signal is coming in OFF P SAVE power save mode GRAY B gray screen DELAY TIME Select the period until the screen status changes as selected in NO SYNC ACTION after signals stop coming in 30sec 5min 15min LOW LATENCY Activates deactivates the function to shorten the time taken to display the picture low ...

Страница 16: ... input NTSC signal 00 compliant with 0 set up signal 7 5 compliant with 7 5 set up signal COMPO LEVEL Select the level of the analog component signal 480i and 576i only B75 compliant with BetacamVTR 7 5 set up signal B00 compliant with BetacamVTR 0 set up signal SMPTE compliant with M2VTR signals sub menu Display the sub menu which enables you to adjust the items in PICTURE SUB ADJ while viewing t...

Страница 17: ...ems in SIZE POSI ADJ 1 Memorized for each signal format WHITE BALANCE SET Selects the GAMMA correction value color temperature and adjusts the drive level and cutoff point of each color R G B Item To do Setting value GAMMA Select the GAMMA correction value 2 2 equivalent to Υ 2 2 2 35 equivalent to Υ 2 35 2 4 equivalent to Υ 2 4 2 6 equivalent to Υ 2 6 COLOR TEMP Select the color temperature 9300K...

Страница 18: ...ge 7 AUTO OFF ON TIME CODE Select the type of the TIME CODE display VITC 2 LTC 2 D VITC CRC ERROR Select whether the CRC error indication for the input HD SDI signal is displayed on the screen On the Information Display on page 7 ON OFF SUB HOUR METER Display the hours of use unit hour You can reset this item MODEL Display the model name of the monitor VERSION Display the version of the monitor HO...

Страница 19: ...ct AUTO Select COMPO RGB or PC when the picture is not displayed correctly with AUTO DVI D input of the monitor is compatible with HDCP all reset Restores all the settings and adjustments of the monitor to the default HOUR METER and the settings done by using the adjustment knobs on the front panel will not be reset When you operate the monitor with the AC power supply the monitor is turned off on...

Страница 20: ...cially available Consult your dealer if you need it Serial communication For the details see page 22 PC etc RS 485 IN or RS 232C RS 485 OUT RS 485 IN RS 485 OUT RS 485 IN RS 485 OUT 7 Using the MAKE TRIGGER system The MAKE TRIGGER terminal is configured as follows You can assign a function to each pin terminal in REMOTE SETTING PIN1 PIN2 PIN3 PIN4 PIN5 in PARALLEL TYPE on page 18 You cannot change...

Страница 21: ...information is displayed only at the moment of short circuiting 5 While controlling with the MAKE system the level meter is switched between displayed short circuiting and hidden opening When LEVEL METER ch is set to OFF the level meter is not displayed NO EFFECT appears While controlling with the TRIGGER system the pattern of the audio channel display is switched 6 While controlling with the MAKE...

Страница 22: ...mmunication termination command 00BCN0Cr 6Monitor s status 00BOKCr 4Monitor s status 00BOKCr 2Monitor s status 00BOKCr PC etc Example of communication procedures Monitor External Control cont This is a female terminal The 7th terminal and the 8th terminal are connected Pin No Signal 1 NC 2 RXD 3 TXD 4 NC 5 GND 6 NC 7 RTS 8 CTS 9 NC Pin No IN terminal signal OUT terminal signal 1 TXD TXD 2 TXD TXD ...

Страница 23: ...W 0 Cr Turns off the monitor on standby No data 15 1 B I N A Cr Selects SDI 1 input No data 16 1 B I N B Cr Selects SDI 2 input No data 17 1 B I N C Cr Selects DVI input No data 18 1 B I N D Cr Selects COMPO input No data 19 1 B I N E Cr Selects VIDEO input No data 20 1 B D I S P Cr Displays the status 3 No data 21 1 B A M U T E x x 2 Cr Turns muting on off 00 Off 01 On 22 1 B A S P x x 2 Cr Chang...

Страница 24: ... displayed for a long time it may remain indistinctly on the screen after the picture has changed Though the remaining picture will disappear after a while there may be a case that it remains for a long period depending on the length of time the still image was displayed for This is due to the characteristics of the LCD display and is not a malfunction Red spots blue spots and green spots on the p...

Страница 25: ...ance of the screen such as uneven color discoloration scratches be careful about the following Do not paste or stick anything using any glues or adhesive tapes Do not write anything on the screen Do not strike the screen with a hard object Avoid condensation on the screen Do not wipe the screen with solvent such as alcohol thinner or benzine Do not wipe the screen forcefully Wipe stains off the sc...

Страница 26: ...x 1 for external battery 7 Input output terminals Video VIDEO Input output of composite signal 1 line BNC connector x 2 1 V p p 75 Ω The input IN and output OUT terminals are bridge connected auto termination DVI D HDCP DVI D signal input compatible with HDCP DVI D connector x 1 compatible with DDC2B COMPO Y PB B Y PR R Y Input output of analog component signal 1 line BNC connector x 6 Y 1 V p p 7...

Страница 27: ...s Unit mm inch Front view Side view Rear view 100 VESA mounting holes Size 4 M4 depth 10 mm 100 115 4 5 8 240 9 1 2 430 17 309 12 1 4 349 8 13 7 8 314 5 12 1 2 199 7 7 8 1 3 1 16 102 4 1 8 56 2 1 4 18 3 4 3 1 8 DT V17G1_EN indd 27 DT V17G1_EN indd 27 09 12 3 7 55 24 PM 09 12 3 7 55 24 PM ...

Страница 28: ...DT V17G1_EN indd 28 DT V17G1_EN indd 28 09 12 3 7 55 24 PM 09 12 3 7 55 24 PM ...

Отзывы: