background image

DM-NE300E

LST0165-001B

DM-NE300E MPEG-2 NETWORK ENCODER

MPEG-2 NETWORK ENCODER

B

Instruction Manual

POW

ER

STREAM

DM-NE300E MPEG-2 NETWORK ENCODER

HO

LD

HOLD

USER

2M

bps

2Mbps

3M

bps

3Mbps

4M

bps

4Mbps

5M

bps

5Mbps

6M

bps

6Mbps

10M

bps

10Mbps

15M

bps

15Mbps

HO

LD

USER

2M

bps

3M

bps

4M

bps

5M

bps

6M

bps

10M

bps

15M

bps

This instruction book is made from 100% recycled paper.

Содержание DM-NE300E

Страница 1: ...R B Instruction Manual POWER STREAM DM NE300E MPEG 2 NETWORK ENCODER HOLD HOLD USER 2Mbps 2Mbps 3Mbps 3Mbps 4Mbps 4Mbps 5Mbps 5Mbps 6Mbps 6Mbps 10Mbps 10Mbps 15Mbps 15Mbps HOLD USER 2Mbps 3Mbps 4Mbps 5Mbps 6Mbps 10Mbps 15Mbps This instruction book is made from 100 recycled paper ...

Страница 2: ...generate radiation X rays or corrosive gases 䡵 Handling the unit Please do not place heavy objects on the unit like a monitor on TV Please keep the mobile rack into the compartment As injury may result from fingers getting clamped Please do not block the ventilation openings Avoid violent shocks to the unit Do not drop the unit 䡵 Maintaining the unit Please turn off the power before performing mai...

Страница 3: ... connected to the terminal in the plug which is marked with the letter E or by the safety earth sym bol or coloured GREEN or GREEN AND YELLOW The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or which is coloured BLACK The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED POWER SYSTEM C...

Страница 4: ...s Geräts mit Umsicht vor um Verletzungen zu vermeiden Decken Sie niemals die Lüftungsöffnungen ab Setzen Sie das Gerät keinerlei Erschütterungen und Schlägen aus und lassen Sie es nicht fallen Trennen Sie den Netzadapter vom Netz wenn Sie das Gerät nicht benutzen Sie sparen auf diese Weise Energie 䡵 Reinigung Schalten Sie das Gerät unbedingt ab bevor Sie die Reinigung durchführen Wischen Sie das G...

Страница 5: ...en E oder dem Schutzerdesymbol markiert oder GRÜN bzw GRÜN GELB farbkodiert ist Der BLAU markierte Leiter muss an den Kontakt des Steckverbinders angeschlossen werden der entweder mit dem Buchstaben N markiert oder SCHWARZ farbkodiert ist Der BRAUN markierte Leiter muss an den Kontakt des Steckverbinders angeschlossen werden der entweder mit dem Buchstaben L markiert oder ROT farbkodiert ist VERSO...

Страница 6: ...Bedienfeld und überstehende Teile Gewicht 2 8 k 䡵 Technische Daten und äußeres Erscheinungsbild können ohne vorherige Ankündigung geändert werden Filterklemme befestigen Montieren Sie die beiliegende Filterklemme wie nachfolgend abgebildet an dem zum DM NE300E weisenden Ende des DV Kabels zur Fixierung anziehen Filterklemme überstehende Enden kürzen ACHTUNG 5 ...

Страница 7: ...schluss Kabel Länge VIDEO OUT 1 KOAXIALKABEL GESCHIRMT 10 Meter VIDEO OUT 2 S KABEL GESCHIRMT 10 Meter AUDIO OUT LEFT CINCHKABEL RCA GESCHIRMT 10 Meter AUDIO OUT RIGHT CINCHKABEL RCA GESCHIRMT 10 Meter DV 9V DV KABEL GESCHIRMT 4 Meter LAN CAT5 STP KABEL 100 Meter COM D SUB KABEL 9 POLIG GESCHIRMT 10 Meter AC IN AC NETZTEIL NETZKABEL 2 5 Meter Der Einschaltstrom dieses Geräts beträgt 12 0 Ampere Ac...

Страница 8: ... compliant Multicast Unicast is available Sends Receives serial control data via UDP 2U half rack size Mounting onto EIA rack is possible Use of a mount bracket to be purchased separately is required This encoder and decoder have some delay of audio video due to the nature of the MPEG format This equipment comes equipped with a Normal mode that gives priority to video quality as well as a Low Dela...

Страница 9: ...the process and failure may occur during startup NetBIOS of Windows based Computer When NetBIOS of Windows based computers are enabled broadcast packets may be sent regularly which may occupy the network and lead to failure in stream transmission from this equipment as well as stream reception at the decoder Disable NetBIOS when connecting Windows based computers to the same LAN To alter NetBIOS s...

Страница 10: ... To set to output bitrate of USER s preset value Factory setting is at 1 5 Mbps Low Delay Lights up when selected 9 HOLD Switch To lock unlock the above switches Switches are locked when light is on Press this button to unlock before operating the switches Light turns off when unlocked The above switches will be automatically locked if left unoperated for 10 seconds 0 STREAM LED Lights up when str...

Страница 11: ...422 Turn OFF the power of this equipment when oper ating this switch LINK LED Lights up when this equipment is connected to a network 100BASE TX Terminal 100BASE TX terminal Output terminal for MPEG 2 stream RXD LED Lights up when this equipment receives packet via 100BASE TX fi AC IN AC 220 V 240 V inlet Ensure to use the power cord supplied for connection Make sure to earth the equipment Do so be...

Страница 12: ...anged settings and hence the same operation prior to turning off can be performed by just turning on the power Setting need not be performed every time when turning on the power 1 Turn ON the power switch on the front panel The POWER LED and USER button will light up in green 2 Wait for about 20 seconds for it to be activated Upon activation the HOLD button and other buttons that have been used pr...

Страница 13: ...nput Analog audio 2 Vrms RCA pin x 2 LR DV input DV input DV terminal x 1 Network interface 100 BASE TX RJ 45 x 1 External control RS232C RS422 D sub9Pin male x 1 Maintenance RS 232C D sub9Pin female x 1 Stream control RTSP TCP IP manually Stream output 100 BASE TX RTP UDP IP unicast multicast Output rate 1 08 Mbps 13 5 Mbps Output format MPEG 2 Transport Stream ISO IEC13818 1 TS packet size 188 b...

Страница 14: ...xceeding the following lengths Port Cable Length VIDEO IN SHIELDED COAXIAL CABLE 10 meters Y C IN SHIELDED S CABLE 10 meters AUDIO IN L SHIELDED RCA PIN CABLE 10 meters AUDIO IN R SHIELDED RCA PIN CABLE 10 meters DV IN SHIELDED DV CABLE 4 meters 100BASE TX CATEGORY 5 TWIST PAIR SHIELDED CABLE 100 meters SERIAL SHIELDED 9PIN D SUB CABLE 10 meters AC IN AC POWER CABLE 2 5 meters The inrush current o...

Страница 15: ...tory Setting Supplementary Note IP Address 10 0 0 1 Subnet Mask 255 0 0 0 Default Gateway Address NIL Bitrate 3 Mbps Low Delay Normal Normal Mode selected Audio ON Audio Stream available Auto Start Normal Manual Start selected Unicast Multicast Mode Unicast Unicast Mode selected Multicast Stop Mode Stopped when all decoders stop When all decoders stop selected Multicast IP Address 225 0 1 1 Multic...

Страница 16: ...re trademarks or registered trademarks of their respective companies 1 All rights are reserved with regard to a portion or the entire manual 2 Contents of this booklet may be altered without any prior notice 3 Our company shall not be responsible for any eventualities arising from the operation of this equipment 4 Photos and diagrams are enlarged omitted or composited to ease explanation and may s...

Страница 17: ... 0 1 and 255 0 0 0 respectively 2 Starting Up Browser Software Start up the Internet Explorer Version 5 5 or later on the computer followed by entering DM NE300E s IP ad dress URL in the URL input field For example if the IP address of DM NE300E is 10 0 0 1 then key in the URL http 10 0 0 1 and press Enter The top page will be displayed on the browser If the top page is not displayed check if the ...

Страница 18: ...nd these can be altered at the same time To make alterations select or enter a value followed by clicking the Enter button on the bottom left Links to other pages are located on the uppermost portion of the page When entry is correct When entry is incorrect The Basic screen will be displayed again vx x vx x ...

Страница 19: ...ransmitted to multiple decoders at one time To perform multicast transmission select the Multicast mode Multicast Stop Mode All Decoders Master Decoder or Manual can be chosen When All Decoders is selected multicast transmission stops when all decoders participating in the multicast stop receiving data When Master Decoder is selected multicast stops when the first decoder to start receiving data M...

Страница 20: ...cify destination IP address for transmission by unicast using 4 decimal integers Destination Port Number Unicast Destination Port Number Specify the destination port number between 0 and 65535 Numbers below 1023 may be used by various protocols Values above 1024 are recommended Multicast Address Multicast Destination IP Address Specify multicast IP address for transmission by multicast using 4 dec...

Страница 21: ...15 Screen During Transmission Screen when destination IP address does not respond to Ping in the Unicast mode vx x vx x vx x ...

Страница 22: ...combination Screen when decoder does not respond to Ping Target Decoder IP Address Enter the IP address for the DM ND300E decoder for which Play Stop is to be performed Target Encoder IP Address Enter the IP address of the DM NE300E encoder to be accessed by the decoder IP address of the DM NE300E currently accessed via the browser is automatically specified during the initial state Play Stop Butt...

Страница 23: ...as current settings Updated every 30 seconds 12 1 7 Joining Decoders List of Joining Decoders Displays the IP address of the decoder that is decoding the bit stream of this equipment Display of decoder currently in the decoding process is updated every 30 seconds x x vx x vx x ...

Страница 24: ... is currently accessing the equipment Alteration of settings by multiple parties is not advisable as this may give rise to confusion If the browser is closed without logging out web server of this equipment will remain active until timeout and warning messages will be sent to others who subsequently access the equipment The equipment will be informed immediately that access via the browser has end...

Страница 25: ...Subnet mask Default gateway IP Address Self IP Address Use this to alter the IP address of DM NE300E Enter 4 decimal integers Self IP address column cannot be left unfilled Subnet mask Enter 4 decimal integers as well for subnet mask Note Factory settings of IP address and subnet mask are 10 0 0 1 and 255 0 0 0 respectively Default Gateway Use this to specify the default gateway Enter 4 decimal in...

Страница 26: ...creen 12 1 10 Password Alteration Page Password entered at the top page can be altered here Enter the current and new passwords and click the Enter button A screen requesting for re entry of password will be displayed Re enter the new password Maximum number of characters for the password is 14 alphanumeric characters case sensitive Password Alteration Completed Screen vx x vx x vx x vx x ...

Страница 27: ...lue can be specified between 1 and 254 Data Protocol Protocol Storing Data Protocol for storing MPEG 2 data in UDP packet can be selected RTP is selected in the factory settings If MPEG Only is selected RTP header will not be added and only MPEG data will be stored in UDP payload Ensure to make use of RTP when decoding by DM ND300E MPEG2 TS Packet Number Number of MPEG 2 TS Packets Stored in UDP P...

Страница 28: ...s To restore all parameters to their factory settings Parameters upon restarting will become values as displayed on this page IP address becomes 10 0 0 1 Note This operation restores DM NE300E network parameters to its factory settings and connection via previous network will be unavailable 12 More Details on Settings ...

Страница 29: ...be displayed in the terminal by pressing the Enter key when starting up DM NE300E Commands can be entered in this state Note Connection cannot be established via terminal software if Telnet is connected 12 2 2 List of Commands 1 Setting commands for which reboot is not required Bitrate Alteration Command ChangeBitrate Argument Bitrate in units of Mbps Be sure to set to 1 decimal place or more For ...

Страница 30: ...in double quotation marks Separate the decimal integers using periods when entering the IP address Select address between 224 0 0 0 and 239 255 255 255 Example ChangeMulticastAddress 225 0 1 1 Operation Alters destination address of multicast transmission Destination Port Number Alteration Command ChangeMulticastPort Arguments Port Number 0 65535 Example ChangeMulticastPort 10000 Operation Alters ...

Страница 31: ...erial port in the flow control mode Destination IP Address Command ChangeDestinationAddress Argument IP address enclosed in double quotation marks Separate the decimal integers using periods when entering the IP address Example ChangeDestinationAddress 10 0 0 100 Operation Alters destination IP address for unicast Destination address when transmitting data manually from DM NE300E The destination I...

Страница 32: ...s altered using the commands below Reboot using either the power ON OFF or reboot command Reboot command is recommended for consistency of nonvolatile memory Reboot command is reboot Self IP Address and Subnet Mask Alteration Command ChangeIPAddress Argument Enter the IP address in double quotation marks in the initial argument and the subnet mask in double quotation marks in the second argument S...

Страница 33: ...eceiving data Error Log Display Command ErrorLog Argument Nil Operation Displays error log List of Commands Command Help Argument Nil Operation Displays list of commands in alphabetical order 4 Stream Control Command Start Transmission Command Play Argument Nil Operation Starts manual stream transmission from DM NE300E When in the Unicast mode data is transmitted to the destination address specifi...

Страница 34: ...sword for DM NE300E are User Name user_name Password password Note It is recommended that user name and password be changed immediately for security reasons To make alterations use the ChangeTelnetPassword command as mentioned above When you want more display lines on Telnet increase the buffer size in the Telnet Software Settings Note Only 1 Telnet can be connected at one time Connection is not p...

Страница 35: ...29 ...

Страница 36: ...CODER LST0165 001B VICTOR COMPANY OF JAPAN LIMITED is a registered trademark owned by VICTOR COMPANY OF JAPAN LTD is a registered trademark in Japan the U S A the U K and many other countries 2003 VICTOR COMPANY OF JAPAN LIMITED ...