63
ENGLISH
2-3. Parameters used for the data format
The following three kinds of parameters are prepared for the control command and response data.
(1) Numeric value
Designates the 2-byte hexadecimal value with the sign as the 4-digit (byte) characters.
Designation allowable range : “8000” to “7FFF”
(2) ON/OFF
Designates the status (ON/OFF) of the projector, such as POWER and HIDE.
Character
Hex.
Meaning
“0”
30
OFF
“1”
31
ON
(3) Special parameters
Input switching parameters:
Character
Hex.
Meaning
“1”
30
VIC1
“2”
31
VIC2
“3”
33
VIC3
Operation mode parameters:
Character
Hex.
Meaning
“0000”
30h 30h 30h 30h
Stand-by mode
“0001”
30h 30h 30h 31h
Power-on mode
“0002”
30h 30h 30h 32h
Cool-down mode
“0004”
30h 30h 30h 34h
Warning mode
3. Control command table
The control commands that can be sent from the computer are as follows:
Function
Command
Asking
Kind of data
Power ON
ELSE
Numeric Value
ON/OFF
Special Data
OPERATE
U0F
–
–
–
✓
–
HIDE
U00
✓
–
–
✓
–
Right Left rev.
U17
✓
–
–
✓
–
Keystone
U40
✓
–
✓
–
–
Input
U1A
✓
–
–
–
VIC1, VIC2, VIC3
Operation mode
Z03
✓
✓
–
–
Stand-by, Power-on,
Cool-down, Warning
* Keystone: Numeric value can range from “FF80” to “0080”
* Operation mode: Only Asking command is possible
Specifications (Cont.)
EN59-63QX1G_f.pm6
02.3.7, 13:39
63
Содержание DLA-QX1G - D-ila High Resolution Projector
Страница 2: ......
Страница 3: ...SUPER PROJECTOR DLA QX1G INSTRUCTIONS ENGLISH ...
Страница 66: ...Memorandum ...
Страница 67: ...SUPER PROJECTEUR DLA QX1G MANUEL D INSTRUCTIONS FRANÇAIS ...
Страница 130: ...Memorandum ...
Страница 131: ......