49
Getting Started
Preparation
Basic
Operation
S
ettings
Troubleshooting
Othe
rs
ENGLISH
This section shows the communication examples of RS-232C.
Operating command
Reference command
RS-232C Communication Examples
Type
Command
Description
Connection check
PC
This unit: 21 89 01 00 00 0A
This unit
PC: 06 89 01 00 00 0A
Checks connection
Power (On)
PC
This unit: 21 89 01 50 57 31 0A
This unit
PC: 06 89 01 50 57 0A
When power is turned on from standby mode
Power (Off)
PC
This unit: 21 89 01 50 57 30 0A
This unit
PC: 06 89 01 50 57 0A
When power is turned off (standby mode)
from power-on mode
Input (COMP.)
PC
This unit: 21 89 01 49 50 32 0A
This unit
PC: 06 89 01 49 50 0A
When video input is set to component
Remote Control
(MENU)
PC
This unit: 21 89 01 52 43 37 33 32 45 0A
This unit
PC: 06 89 01 52 43 0A
When the same operation as pressing the
[MENU] button on the remote control is made
Type
Command
Description
Power (On)
PC
This unit: 3F 89 01 50 57 0A
This unit
PC: 06 89 01 50 57 0A
This unit
PC: 40 89 01 50 57 31 0A
When information on power-on mode is
acquired
Input (S-VIDEO)
PC
This unit: 3F 89 01 49 50 0A
This unit
PC: 06 89 01 49 50 0A
This unit
PC: 40 89 01 49 50 30 0A
When information on S-VIDEO input is
acquired
DLA-HD1D_EN.book Page 49 Tuesday, January 30, 2007 2:54 PM
Содержание DLA-HD1
Страница 54: ...6 54 Others Memo ...