20 (No.PA062<Rev.001>)
5.3
LOG (SELF-DIAGONOSIS RECORD AND INDICATION)
5.3.1 OUTLINE
By using the special setting and adjustment software, data relat-
ed to abnormal operation (history) stored in the projector can be
load.
On the basis of contents "LED (INDICATOR) WARNING INDI-
CATONS" set and lamp use time, internal and external tempera-
ture, and the data prior to the previous usage time can be viewed
as a table.
READING PROCEDURE
(1) Run ServiceCommander Software
(2) Select Port, click [Connect] to connect the PC and the
projector.
(3) select Log menu
(4) Click to the [Read from set]
The first number is error code.
(5) Click the [Save to File] button and save the TEXT file to
PC.
(6) Click the [Clean Log] button and delete all data stored in
projector.
Fig.5-1 "Error log" screen
ERROR LOG
EVENT LOG
Error code
Content
01
Outside air temperature abnormality
02
Inside air temperature abnormality
03
Temperature abnormality of Rch D-ILA device
04
Temperature abnormality of Gch D-ILA device
05
Temperature abnormality of Bch D-ILA device
09
Temperature abnormality of the DD PWB VPM
0A
Temperature abnormality of DD ASIC
0B
Temperature abnormality of DD ASIC
0F
Temperature is not detected
1A
Interlock of lamp door detected abnormality
30
Fan error detected
31
Power exhaust fan is abnormal (stop)
32
Power intake fan is abnormal (stop)
33
Lamp/PCS cooling fan is abnormal (stop)
34
B device cooling fan is abnormal (stop)
35
RG device cooling fan is abnormal (stop)
37
DD FPGA fan abnormal (stop)
38
DD ASIC fan abnormality (stop)
39
Lamp exhaust fan is abnormal (stop)
70
Lamp usage time over
80
CPU PWB is abnormal
86
Receiving error of HDMI
90
Device communication error (Do not transition
to emergency)
91
DD FPGA does not start up
92
DD VPM CPU does not start up
93
Communication error of DD FPGA
94
DD PWB does not start up
95
Communication error of DD ASIC
96
Communication error of DD PWB
97
Communication error of DD ASIC
98
Power supply error of D-ILA device
9A
Rch D-ILA device is not connected
9B
Rch D-ILA device is not connected
9C
Gch D-ILA device is not connected
9D
Gch D-ILA device is not connected
9E
Bch D-ILA device is not connected
9F
Bch D-ILA device is not connected
A1
Power PWB is abnormal
A3
Power on sequence error
A5
Communication error with C.SENS PWB
A6
Light quantity balance is abnormal
AA
Mecha CPU does not start.
AB
Communication error with Mecha CPU
B0
USB memory was disconnected during FW up
by USB
B1
LAN line disconnected during FW up via LAN
line
B2
Main FW up failed
B3
VPM FW up failed
B6
Mecha FW up failed
B7
HDMI_DRV FW up failed
B8
CMS_DATA FW up failed
B9
USB file format system is different
BA
UP data file (number of files) is insufficient
Event code
Content
F0
Recorded after power is turned on
(After D-ILA logo is displayed)
F1
Record after 1 hour after power is turned on
F2
Recorded after power OFF operation (receiv-
ing)
FA
Power OFF is executed by the Off Timer func-
tion
FB
Power OFF is executed by the ECO Mode func-
tion
E0
VP: Confirm "TMDS LOCK"
Error code
Content