12.4 Phase :
’
U04
’
(55H 30H 34H)
Definition
:
Adjusts the phase
Command
:
‘U04’(55H 30H 34H)
Parameter type
:
Numeric
Reply time
:
3seconds
Conditions
:
Eexcept when there is no Source (Area) signal
Operation mode
Standby
mode Power ON mode
Cool-down mode
Emergency mode
X O
X
X
#
Communication Examples
◇
When specifying "50" (decimal) as the phase adjust level
CTLR ‘!’ ‘1’ SP ‘U04’ SP ‘0032’ CR
DLA ‘@’ ‘1’ SP ‘0’ CR
◇
When requesting the current phase adjust level (if phase adjust level is set to "0" (decimal))
CTLR ‘?’ ‘1’ SP ‘U04’ CR