background image

16

OTHERS

Error output

When an abnormality is detected, error notification is provided by LED illumination, error indication on the display and error
output to the [ALARM] connector.

1. LED lighting

The [STATUS], [INPUT] or [SYNC] indicator on the front panel
lights orange (warning) or red (error), depending on the type of
error.

2. Display indication

The first line of the display shows a description of the error.  When
the menu is displayed, errors are not shown.

Memoranda:

With LOCAL, the error indication is shown when the error is
detected and goes out when the error is no longer detected.
With REMOTE, once an error is detected, the indication
remains (goes out when the switch is set to LOCAL).

Error codes with 2 to 6 digits may be shown at the same time.
In this case, report the error codes to your JVC dealer.

3. [Alarm] connector output

2-line alarm output terminals are provided for the rear panel’s
[ALARM] connector.  Terminals A and B are short-circuited (relay
contact) when an error occurs or the power is turned off.  Normally,
these terminals are open.  (For open and short-circuited conditions,
refer to the table on the next page.)
The maximum rated value is 30 V 0.5 A for AC/DC with non-
inductive load.

Pin assignment of the [ALARM] connector

D

[

1

1 0 8

4 : 3 ]

0

Fa n

E r r o r

POWER

LOCAL REMOTE

STATUS

INPUT

SYNC

MENU

ENTER

ESC

BC-D2300U HDTV UP CONVERTER

STATUS

INPUT

SYNC

D

[

1

1 0 8

4 : 3 ]

0

V. D a t a

E r r o r 0 3

POWER

AC IN

ALARM

REMOTE-IN

REMOTE-OUT TERMINATE

OFF ON

LOOP
THROUGH

IN

OUT

SDI

1

2

3

HD SERIAL OUT

REF

Pb

Y

Pr

CVBS

CN1

ON

OFF

FUSE

1.6A(125V)

FUSE

9

6

5

1

9

6

5

1

9

6

5

1

ALARM

1

5

9

6

Pin

Name

Contents

number

1

NC

Unconnected

2

(RD)

(Reception data for maintenance)

3

(SD)

(Transmission data for maintenance)

4

ALARM2-B

Alarm output 2 B terminal

5

GND

Signal ground

6

ALARM2-A

Alarm output 2 A terminal

7

ALARM1-A

Alarm output 1 A terminal

8

ALARM1-B

Alarm output 1 B terminal

9

NC

Unconnected

Front panel

Error indication

Display

Rear panel

17

Error output (contd.)

Error

Error contents

LED

ALARM 1

ALARM 2

indications

Power Error

Abnormality in the power unit

STATUS: Red

Short-

Open

Fan Error

Abnormality in the fan motor

circuited

Data No-input

No video and audio signal is input.

INPUT: Orange

Open

Open

(warning)

V. Format Error

Format error of the SDI input signals

INPUT: Red

Open

Short-

V. Data Error

Error of video data in the SDI input signal

circuited

A. Data Error

Error of audio data in the SDI input signal

REF No-input

No external sync signal is input (note)

SYNC: Red

Short-

Open

SD Unlock

Synchronization is not possible due to incorrect

circuited

video input signals

Ref Unlock

Synchronization is not possible due to incorrect
external sync signal input

Comm Error

Abnormal remote communication

STATUS: Red

Short-

Open

Device Error

Abnormality in the internal device

circuited

——

Power is turned off.

——

Short-

Short-

circuited

circuited

Error indications and output contents

Note: When an incorrect external sync signal is input, the REF No-input error indication may be shown.

When an error indication is shown, check the input signal and connections according to type of error indicated.  When this
unit malfunctions, consult your nearest JVC authorized service agent.

See "1.4 About Error Messages" 

on page 1-3.

Содержание BC-D2300U

Страница 1: ...IONS HDTV UPCONVERTER BC D2300U SS961574 002 R POWER LOCAL REMOTE STATUS INPUT SYNC MENU ENTER ESC BC D2300U HDTV UP CONVERTER For Customer Use Enter below the Serial No which is located on the top cover Retain this information for future reference Model No BC D2300U Serial No Thank you for purchasing this JVC product Before operating this unit please read the instructions carefully to ensure the ...

Страница 2: ...justment of other controls may result in damage and will often require extensive work by a qualified technician to restore the appliance to normal operation e If the appliance has been dropped or the cabinet has been damaged f When the appliance exhibits a distinct change in performance this indicates a need for service 18 When replacement parts are required be sure the service technician has used...

Страница 3: ...ne or thinner as these may deform or discolor the cabinet surface To remove excessive dirt clean the unit with a mild detergent diluted with water then wipe it with dry cloth Do not use the unit in an environment exposed to gases generated by chemicals or organic solvents INSTALLATION IN A RACK This unit can be installed in EIA standard rack Ensure sufficient rack strength by attaching L metal sup...

Страница 4: ...emote control this unit set the LOCAL REMOTE switch on the front panel to REMOTE REMOTE OUT connector D sub 9 pin female Outputs the control signals input to the REMOTE IN connector or 0 ALARM connector as signals conform ing to the RS 485 serial interface Connect this connec tor to the REMOTE IN connector of another device Up to 31 devices can be connected in series with this connection TERMINATE...

Страница 5: ... selected settings are recalled When completed the completion display is shown Memorandum When the check screen is shown press the ESC button to cancel it The previous Profile Load menu setting display is restored 6Press the ENTER MENU button or ESC button Menu setting display is restored and the recalled menu settings are activated 7Press the ESC button to restore the normal display Memorandum Th...

Страница 6: ...ntents contd The items in the shaded area are shown when the optional software is installed Factory Setting Items V Position Motion Sense Enhance Level Variable Enhancer Enhance Level Enhance Freq Cut Off Freq Threshold Noise Reduction Settings 63 0 63 0 8 15 5 0 15 OFF ON 5 0 15 2 4 5 3 7 0 15 OFF ON Contents Adjusts the picture s vertical position varies in 63 lines Note When Output Mode is set ...

Страница 7: ...re will be monochrome if the Back Color L is set to 0 black or 100 white This item is shown only when the Back Color Mode is set to HSL Sets the background color hue In most cases the following colors can be obtained 0 Red 120 Green 240 Blue This item is shown only when the Back Color Mode is set to HSL 13 Items Color Correction White Level Black Level White Color B White Color R Back Color B Back...

Страница 8: ...ry Setting Items Administration Remote ID Remote Speed Remote Port Active Line Alarm Name Version Serial No License key Running Time Settings 1 31 9600 19200 38400 REMOTE IN ALARM 480 486 OFF ON BC D2300 Contents Press the ENTER MENU button to enter the administration sub menu The following nine items can be set on the administration sub menu Sets the remote ID of this unit to remote control this ...

Страница 9: ...EF Pb Y Pr CVBS CN1 ON OFF FUSE 1 6A 125V FUSE 9 6 5 1 9 6 5 1 9 6 5 1 ALARM 1 5 9 6 Pin Name Contents number 1 NC Unconnected 2 RD Reception data for maintenance 3 SD Transmission data for maintenance 4 ALARM2 B Alarm output 2 B terminal 5 GND Signal ground 6 ALARM2 A Alarm output 2 A terminal 7 ALARM1 A Alarm output 1 A terminal 8 ALARM1 B Alarm output 1 B terminal 9 NC Unconnected Front panel E...

Страница 10: ...gnal SMPTE259M 1 line 0 8 Vp p 75 ohms unbalanced active through Bit rate 270 Mbps Embedded audio signal 4 ch sampling frequency of 48 kHz Sync signals Sync signal 75 ohms unbalanced loop through 1 line B B 0 45 Vp p NTSC HD SYNC Positive and negative bipolarity tri sync signal of 600 mVp p 300 mVp p 5Output signal Video and audio HD digital serial signal SMPTE292M 3 lines 0 8 Vp p 75 ohms unbalan...

Страница 11: ...1 9 6 5 1 9 6 5 1 Design and specifications subject to change without notice Specifications contd OTHERS 21 Supplement Put L metal supports on the both sides of EIA rack to secure strength Attaching the L metal support on EIA rack EIA rack L metal support L metal support Screw Min 420 Min 70 45 Thickness 2 mm L metal support Rack mounting is optional Use only with racks that have fully adjustable ...

Страница 12: ...22 MEMO 23 MEMO ...

Отзывы: