Item
Measuring
instruments
Test point
Ad justment part
Description
H-SHIFT
adjustment
Signal
generator
Remote
control unit
H-SHIFT
1.
Receive a c ircle pattern s ignal.
2.
Select H-SHIFT with the UP/DOWN ( / ) key.
3.
Adjust H-SHIFT with the LEFT/RIGHT ( / ) key to make
C= D
.
4. Check and readjus t H-SHIFT item if the adjustment
becomes improper after s ome other geometric adjustments
are done.
5.
Press the INFORMATION key and memorize the set value.
H-SIZE
adjustment
Signal
generator
Remote
control unit
H-SIZE
1.
Receive a cross-hatch signal.
2.
Select H-SIZE with the UP/DOWN ( / ) key.
3. Adjust H-SIZE with the LEFT/RIGHT ( / ) key till vertical
lines on both the left and right part of the cross-hatch will be
vis ible nor screen will be s o wide.
4.
Check and readjust H-SIZE item if the adjustment bec omes
improper after some other geometric adjustments are done.
5.
Press the INFORMATION key and memorize the set value.
C
D
Screen size
Picture size 100%
very
close
very
close