No. 51917
AV-T2922
19
ADJUSTMENTS
BASIC ADJUSTMENT
Item
Measuring
instrument
Test point
Ad justment item
Description
Check of
B1 POWER
SUPPLY
DC Voltmeter TP-91
(B1 connector
1 pin)
TP-E(
#
)
(B1 connector
3 pin)
1. Receive a black and white signal (color off). (NTSC)
2. Connect the DC voltmeter to B1 c onnector 1 pin (TP-91) and
TP-E(
#
) (B1 c onnector 3 pin).
3. Confirm that the voltage is DC129.5V V.
IF VCO
adjustment
Signal
generator
Remote
control unit
CW TRANSF. (T111)
VCO (CW) mode
"
Under normal conditions, no adjustment is required. And it must
not adjust without signal.
1. Receive the NTSC broadc ast.
2. Select the VCO(CW ) mode from the SERVICE MENU.
3. It c hecks that turn the CW TRANSF and the character of “TOO
HIGH” changes to yellow.
4. Next, it chec ks that turn the CW TRANSF on the c ontrary and
“TOO LOW” changes to yellow.
5. At this time, it checks that “SYNC” is “YES”.
6. Turn the CW TRANSF and it is made for the character of
“BELOW REFERENCE” to bec ome yellow. Again, it checks
that “SYNC” is “YES”.
FOCUS
adjustment
Signal
generator
FOCUS VR
[In HVT]
1. Receive a crosshatch signal.
2. While looking at the sc reen, adjust FOCUS VR so that the
vertical and horizontal lines will be clear and fine in a detail.
3. Make sure that the picture is in focus even when the screen
gets darkened.
+2
-2.5
EXIT BY
IT
VCO (CW)
TOO HIGH
ABOVE REFERENCE
BELOW REFERENCE
TOO LOW
SYNC : YES
EXIT