1-36 (No.52114)
4.7.6
MTS CIRCUIT
Item
Measuring
instrument
Test point
Adjustment part
Description
MTS INPUT
LEVEL
Signal
generator
Remote
control unit
R OUT
[AUDIO OUT]
[3.SOUND (A)]
A01: IN LEVEL
(1) Receive the cross-hatch signal (cross-hatch /
400Hz)
(2) Enter the SERVICE MENU.
(3) Select the < A01 > (IN LEVEL) of the 3.SOUND (A).
(4) Verify that the < A01 > is set at its initial setting value.
(5) Connect the signal generator to R OUT pin of the
AUDIO OUT.
(6) Adjust the MTS input level to 500mV(rms) by < A01 >.
MTS
SEPARATION
TV audio
multiplex
signal
generator
Oscilloscope
R OUT
L OUT
[AUDIO OUT]
[3.SOUND (A)]
A02: LOW SEP.
A03: HI SEP.
(1) Input the stereo L signal (300Hz) from the TV audio
multiplex signal generator to the antenna terminal.
(2) Connect an oscilloscope to R OUT pin of the AUDIO
OUT, and display one cycle portion of the 300Hz
signal.
(3) Enter the SERVICE MENU.
(4) Select the < A02 > (LOW SEP.) of the 3.SOUND (A).
(5) Set the initial setting value of the < A02 >.
(6) Adjust the < A02 > so that the stroke element of the
300Hz signal will become minimum.
(7) Change the connection of the oscilloscope to L OUT
pin of the AUDIO OUT, and enlarge the voltage axis.
(8) Change the signal to 3kHz, and similarly adjust
the < A03 > (HI SEP.).
Adjustment item
A01: IN LEVEL
Initial setting value
10
A02: LOW SEP
Adjustment item
Initial setting value
32
A03: HI SEP
32
L-Channel
signal waveform
R-Channel
crosstalk portion
Minimum
1 cycle