No. 51834
AV-N29302
23
Item
Measuring
instruments
Test point
Adjustment part
Description
[ Method of adjustment without measuring instrument ]
SUB TINT
adjustment
Signal
generator
Oscilloscope
Remote
control unit
TP-R
TP-E(
#
#
#
#
)
[CRT
SOCKET
PWB]
No.4 TINT
1. Receive a broadcast.
2. Select “No.4 TINT” of the PICTURE MODE.
3.
Set the initial setting value of the “No.4 TINT” with the
LEFT/RIGHT key of the MENU.
4. If the tint is not the best with the initial setting value, make fine
adjustment of the “No.4 TINT” until you get the optimum tint.
[ Method of adjustment using measuring instrument ]
1. Input the full field color bar signal (75% white).
2. Select “No.4 TINT” to the PICTURE MODE.
3.
Set the initial setting value of the “No.4 TINT” with the
LEFT/RIGHT key to the MENU.
4. Connect the oscilloscope between TP-R and TP-E.
5. Adjust TINT and bring the value of
(B)
in the illustration to the
voltage
+17V
(V
W-Y
).
Y
Y
Y
Y
W
W
W
W
Cy
G
Mg
R
B
(B)
0V
(-)
(+)