1-20 (No.YA414)
4.8.4 DEFLECTION CIRCUIT
• There are 2 modes of adjustment (setting value) 50Hz mode and 60Hz mode, depending upon the kind of signals (vertical frequency
50Hz / 60Hz).
• When adjusted in 50Hz mode and 60Hz mode will be automatically set.
The setting (adjustment) using the REMOTE CONTROL UNIT is made on the basis of the initial setting values.The setting
values which adjust the screen to the optimum condition can be different from the initial setting values.
• Make sure that the adjustment is properly done on the screen of 60Hz mode.
NOTE:
• Adjust to make both 50Hz & 60Hz are the same v. size and fine straight line.
• When adjust again, adjust 50Hz mode first.
• When adjust in 60Hz mode, only 60Hz mode is adjust.
Item
Measuring
instrument
Test point
Adjustment part
Description
V. HEIGHT /
V. POSITION
Signal
generator
Remote
control unit
[3. DEF]
1. VER. POSITION
3. VER. HEIGHT
(1) Receive a crosshatch signal.
(2) Select 3. DEF from the SERVICE MENU.
(3) Select
< 1. VER. POSITION >
.
(4) Set the initial setting value of
< 1. VER. POSITION >
.
(5) Adjust
< 1. VER. POSITION >
to make the vertical
centre fall on the display centre.
(6) Select
<3. VER. HEIGHT >
.
(7) Set the initial setting value of
<3. VER. HEIGHT >
.
(8) Adjust
<3. VER. HEIGHT >
to make the vertical
screen size be
92%
of the picture size.
Fig.1
H. POSITION
Signal
generator
Remote
control unit
[3. DEF]
2. HOR. POSITION
(1) Receive a circle pattern signal.
(2) Select 3. DEF from the SERVICE MENU.
(3) Select
< 2. HOR. POSITION >
.
(4) Set the initial setting value of
< 2. HOR. POSITION >
.
(5) Adjust <2.HOR. POSITION> to be equal the width of
(A) and (B) as shown in Fig.2.
Fig.2
V.LINEARITY /
V.S-CURVE
Signal
generator
Remote
control unit
[3. DEF]
4. VER. LIN.
5. VER. SCURVE
• If the vertical linearity is noticeably deteriorated, perform
the following steps.
(1) Receive a crosshatch signal.
(2) Select 3. DEF from the SERVICE MENU.
(3) Select
< 4. VER. LIN. >
.
(4) Set the initial setting value of
< 4. VER. LIN. >
.
(5) Select
< 5. VER. SCURVE >
.
(6) Set the initial setting value of
< 5. VER. SCURVE >
.
(7) Adjust
< 4. VER. LIN. >
and
< 5. VER. SCURVE >
so that the space of upper and lower lines as shown
in Fig.3 on TOP, CENTRE and BOTTOM become
uniform.
Fig.3
Screen
size
Picture
size
100%
(A)
(B)
Top
Centre
Bottom